10.3 Accept calibration
FUSION – Storing and recalling data
After a calibration has been completed and the result verified in online state, the calibration
must be accepted.
When a calibration is accepted for one resolution the binary data is stored in the FUSION unit
and will be loaded automatically every time the unit starts up or the resolution is changed to
current. The calibration must be accepted in each resolution.
If no accepted file is available for the actual resolution the unit will go to bypass state when it
starts up.
It is only possible to activate an accepted file if it is generated for the correct resolution.
See Figure 10-5 for administration of accepted files.
- Select "Accept" to accept the current configuration.
- Select "Accept as" to save it to another name.
- Select "Check Auto State" to activate the current accepted file and verify the start up
behaviour.
- "Accepted Files Adminitration" allows the user to copy, rename, delete and activate
accepted files.
Figure 10-5. Accept calibration