Advertisement

4.6 Firewall settings

4.7 Software
4.8 Mounting the FUSION processor in rack
FUSION - Installation and setup
The multi image processing system processor communicates extensively on the network. In
order for it to communicate freely with the FusionNet application, the following ports must be
open in the firewall:
• 22 outbound (SSH)
• 1900 inbound (UPnP open for AutoDiscovery of multi image processing system
processors)
• 30000 outbound (dedicated multi image processing instruction command set)
• 40400 outbound (dedicated ASCII command set)
• 49500 - 49600 inbound (configurational range; one port number per multi image unit)
Note! The firewall must not filter Ping on LAN (ICMP Type 8 (ICMP Echo Request)).
To use multi image processing system, FusionNet.site must be installed on a control PC.
The latest version of the software can be found at www.digitalprojection.com
A license key is required to use the software. The key can be acquired by contacting an
authorised Digital Projection representative.
Each multi image processing system processor is half-width, 1U standard size, so two units
can be combined in a single standard 19" 1RU rack mounting plate, available from Digital
Projection. Remove the upper and lower screws on each side of the multi image processing
system processor, position the mounting plate and reenter the screws as shown in Figure 4-4
and Figure 4-5.
Figure 4-4. Rack mount plate
Figure 4-5. Rack mounted
14