Section 3 Connectors, Switches, and LEDs
Table 3.3
Low (0)/High (1) Switches (S3)
Signal
0
FWE (S3-1)
Low
MD0 (S3-2)
Low
MD1 (S3-3)
Low
IO0 (S3-4)
Low
IO1 (S3-5)
Low
IO2 (S3-6)
Low
- (S3-7)
-
SQMD (S3-8)
Low output from RES
(control sequence 2)
3.2.7

Vcc and PVcc Switches (S5 and S6)

Select Vcc or PVcc level for the control signals according to the flash microcomputer you are
using (to program the flash microcomputer). The Vcc or PVcc level can be selected by the switch
settings of S5 and S6 (see table 3.4). The switches are inside the case. Open the upper panel by
removing the screw in each corner between the upper and lower panels. After switch setting,
reclose the case and refasten the screws.
Table 3.4
Vcc and PVcc Switches (S5 and S6)
Signal
P
FWE (S5-1)
PVcc
MD0 (S5-2)
PVcc
MD1 (S5-3)
PVcc
IO0 (S5-4)
PVcc
IO1 (S6-1)
PVcc
IO2 (S6-2)
PVcc
Rev. 1.00 Oct. 02, 2009 Page 14 of 22
REJ10J2064-0100
1
High
High
High
High
High
High
-
High output from RES
(control sequence 1)
V
Vcc
Vcc
Vcc
Vcc
Vcc
Vcc