2.6.3 Digital EXtra Device Port (Digital XDP) Connection

2.6.3 Digital EXtra Device Port (Digital XDP) Connection
A DPT can be connected to another DPT on the Digital XDP connection. In addition, if the DPT is connected
to a Super Hybrid Port, it can also have an SLT connected in Parallel mode or XDP mode.
Note
Both DPTs must be KX-DT300/KX-T7600 series DPTs (except KX-T7640). Note that the KX-T7667
can only be connected as a slave DPT.
Bluetooth
Modules or USB Modules must not be connected to DPTs in the Digital XDP connection.
®
Parallel mode or XDP mode can be selected through system programming.
If XDP mode is enabled through system programming, parallel connection is not possible. Refer to
"13.1.2 Paralleled Telephone" and "5.1.7 Extension Port Configuration" in the Feature Manual for
further information.
With KX-DT300 Series DPT
Using a Modular T-Adaptor
To DLC4/DLC8 card
To a Super Hybrid Port
(for connection of SLT)
4-conductor wiring cord
Connect pins "D1" and
"D2".
Back View of DPTs
TO TEL
TO MAIN UNIT
/ PABX
96
Installation Manual
Modular
T-Adaptor
4-conductor wiring cord
Connect pins "D1" and "D2".
Master DPT
Cable
Maximum Distance
26 AWG: 30 m (98 ft)
24 AWG: 50 m (164 ft)
22 AWG: 60 m (196 ft)
CAT 5:
50 m (164 ft)
Master DPT
To DLC4/DLC8 card
To a Super Hybrid Port
(for connection of SLT)
2-conductor wiring cord
Connect pins "T" and "R".
SLT