Specification; Terminal Name - Salus RT500 Instruction Manual

Salus programmable thermostat instruction manual
Hide thumbs Also See for RT500:
Table of Contents

Advertisement

PRIOR TO INSTALLING PLEASE READ
THE INSTALLATION GUIDE
The RT500 is easily installed using the Industry Standard
back plate supplied, which can be mounted directly to
the wall surface or a single gang recessed box using the
holes provided; cable entry is from the rear.
The RT500 must be located where it would not be
subjected to extraneous heat gain/loss (such as above
radiators, direct sunlight or in draughts).
Normal household air circulation.

Specification

Switch Rating
: 230V/50Hz/3A
Switch Type
: Single pole, single throw (SPST)
Power Supply
: 2 x AA size Alkaline batteries
Operating Temperature
: 0oC - 50˚C
Temperature Setting Range
: 5oC - 35˚C in 0.5oC steps
Storage Conditions
: -20˚C - 55˚C to 90% RH/non
condensing
Frost Protection Temperature
: Auto cut off at over 35˚C
Battery Low Warning
: 2.6 - 2.8V
Temperature Control Accuracy
: +/- 0.5˚C at 25˚C
Operating Humidity
: 0 to 90% RH/non condensing
Time Display
: 12 hour/24 hour
Clock Accuracy
: +/- 1 min/month
Protection
: Auto cut off at over 35˚C
Memory
: Memory hold up: 5 minutes
Back Light
: EL Panel blue colour
Agency Approval
: CE
Micro disconnection on operation : Type 1.B control action
Rated Impulse Voltage
: 4kV
1
Switches/Jumpers:
The installer should select the jumper positions required
if changing from the factory presets-these jumpers are
found on the rear of the unit.
Switch/Jumpers
Function
Temperature Span
1 Jumper for +/-0.5°C (factory
default setting) or 1.0°C
selection.
Program Type
1 Jumper for 5-2 (factory
default setting) or 7 days
program.
External
1 Jumper.
Back Plate & Wiring
for the RT500
This unit does
not require to be earthed,
earth terminal provided for
safe connection of all earth
wires only.
1) Select a suitable location noting
the advice in page 1 of this
manual, a suitable mounting
height is 1.5m above FFL
2) Isolate AC mains supply, note
this must be 230 Vac and fused at 5 amps.
3) Optimum cable size is 1.5mm CSA; wiring colour codes vary
in different countries and are not defined here.
2
3
4)
Enter cable to rear of back plate.
5)
Securely fix back plate to wall surfa
using holes provided.
6)
Terminate conductors as per the w
unit, ensuring conductors are firm
brass washer.
7)
This appliance is Double Insulated
except at the Earth Parking termin
8)
The Industry Standard back plate h
to the surface of your choice. Pleas
pressure downwards is required to
to connectors in the Back Plate, re
screws at the bottom of the Back P
over tighten.
9)
Fit the batteries supplied and prog
restore AC mains to system when
fully installed and test for correct o
convenience it is possible to install
programme the unit prior to fitting
Terminals:

Terminal Name

Fun
L
Live
SL
Swit
Eart
• Following table is the setting
after reset or Power on: