Parameter Clear - TEC B-670 Series Maintenance Manual

Hide thumbs Also See for B-670 Series:
Table of Contents

Advertisement

6. DIAG. TEST OPERATION
Mode Name

PARAMETER CLEAR

NOTES:
1.
2.
3.
4.
Print tone fine adjustment
(Thermal direct) (KEY)
X axis fine adjustment
Character code selection
Font zero selection
Control code selection
Ribbon type selection
Ribbon motor drive voltage
fine adjustment (PC)
Ribbon motor drive voltage
fine adjustment (KEY)
Strip wait status setting
Stacker
Status response
Threshold manual fine
adjustment for the black
mark sensor
Threshold manual fine
adjustment for the feed gap
sensor
Label pitch
Effective printing length
Effective printing width
With/Without ribbon
Sensor type
Feed Speed
Issue mode
PC save automatic calling
Kanji code
Euro font code
Transmission Control Mode
Reset selection when the
INPUT • PRIME signal is
ON.
Total media distance covered (TL FEED) and the adjustment value for the sensors cannot
be cleared.
Data stored on the flash memory card cannot be cleared with this procedure. To clear dada
on the flash memory card, send the format command to ini tialize the card. For details, refer
to the External Equipment Interface Specification.
For data to be cleared in the RAM clear mode, refer to the RAM clear mode table.
After RAM clear is performed, the threshold setting value will turn to the default (0). When
using pre-printed labels, be sure to set the threshold after referring to the Owner's manual.
Function
Item
Transmissive sensor
6-55
(Revision Date: Dec.10 '99)
6.6 RAM CLEAR MODE
Initial Value
0 step
0.0 mm
PC-850
"0"(without slash)
Auto.
Trans.
0
0
1
OFF
ON
1.0 V
1.4 V
76.2 mm
74.2 mm
128 mm
With
(Feed gap sensor)
5 inch/sec.
Standard
(Batch printing)
ON
TYPE 1
B0H
DTR
ON
EM18-33017