6. DIAG. TEST OPERATION

6.3.15 Euro Font Code Selection

< 1
< 2
E U
NOTES: 1. Holding the [FEED] key or [RESTART] key down for more than 0.5 seconds enables
a fast forward.
2. A changed Euro font code is stored in memory by pressing the [PAUSE] key.
Power off
Turn on the power while
holding down the [FEED]
key and [PAUSE] key.
>
D I A G N O S T I C
Press the [PAUSE] key.
>
P A R A M E T E R
Press the [PAUSE] key 17 times.
R
O
C O D E
Select the Euro font code
with the [FEED] key on
[RESTART] key.
Press the [PAUSE] key.
V 1 . O A
S E T
B O H
[RESTART] key ↑↓ [FEED] key
6-37
EM18-33017
(Revision Date: Jul. 26 '99)
6.3 PARAMETER SETTING MODE
•20H
•FFH