SP Tables
SP5-xxx: Mode
All Indicators On
5001
Turns on or off the all indicators on the operation panel.
mm/inch Selection
5024
Selects the unit of measurement.
After selection, turn the main power switch off and on.
Refill Toner Disp
This SP switches on/off the message that prompts the operator when it is
5051
necessary to replenish toner in the machine.
0: ON (Message displayed (Default))
1: OFF (Message not displayed)
Display IP address
Switches the banner display of the IP address off and on.
[0 to 1/0/1] 0= No, 1= Yes
5055
For example, if this SP is switched on, the IP address will be displayed
below "Ready" while the printer is in standby mode:
Ready
169.254.187.055
Coverage Counter
Display or does not display the coverage counter on the LCD.
5056
[0 to 1 / 0 / 1]
0: Not displayed, 1: Displayed
M047
CÓPIA NÃO CONTROLADA
0: Europe/Asia (mm), 1: North America (inch)
Toner Refill Detect Display
Display IP Address