Management port pinouts
Serial port pinout
Figure 8
ATTENTION! Do not block ventilation openings as this will restrict air flow
around the side and front of the unit. Do not install the SAN Router in an
environment where the operating ambient temperature might exceed 104°F
(40°C).
The SAN Router has two management port connectors, an RS-232
serial connector, and an RJ45 connector.
Figure 8, Serial port pinout
describe the serial port pinout for the SAN Router.
1 2 3 4 5
6
7
Serial port pinout
Serial port pinout description
Table 13
Pin number
Signal
1
DCD
2
RxD
3
TxD
4
DTR
5
Ground
6
DSR
Chapter 2: Installing and connecting the SAN Router
and
Table 13, Serial port pinout description
8 9
Comment
Not used in the SAN Router.
Input of the SAN Router.
Output of the SAN Router.
Output of the SAN Router.
Not used in the SAN Router.
29