San Router Physical Connections; Power Supply Frus - IBM TotalStorage SAN16M-R SAN Installation And Service Manual

San router
Table of Contents

Advertisement

SAN Router physical connections

Power
connections
Figure 14
Fibre channel
ports
50
SAN16M-R SAN Router Installation And Service Manual
Table 19
Physical connections and port locations
Location
Description
4
System status LED
5
Management port status LED
6
Manage port (RJ-45) 10/100
All ports and connectors are located on the front of the SAN Router,
as described in the following paragraphs. The rear of the SAN Router
contains only cooling fans, which are not accessible. The Field
Replaceable Units (FRUs) are the Fibre Channel Port transceivers and
power supplies which include fans.
There are two standard power connections located on the rear of the
SAN Router, one at each end. Each of these power connections
supplies AC power to a different power supply for power
redundancy and backup. Either power supply can support the SAN
Router operation, but it is recommended that both be connected, each
to a different power source to maintain redundancy.
NOTE: If a power supply is not connected, an error message will be
generated.
The two power supplies, located on the rear of the SAN Router are
FRUs (see
Figure
14). To remove a power supply, review
RRP 2: Redundant power

Power supply FRUs

There are twelve user-configurable fibre channel ports located on the
front of the SAN Router, labeled 1 through 12. These port connections
accommodate standard fibre channel transceivers and SFP
supply.
Chapter 5,

Advertisement

Table of Contents
loading

This manual is also suitable for:

2027-r162027-r04

Table of Contents