Sun Microsystems Sun StorEdge A1000 Installation, Operation And Service Manual page 55

Hide thumbs Also See for Sun StorEdge A1000:
Table of Contents

Advertisement

4. Attach the antistatic wrist strap to your wrist and an unpainted metal part of the
chassis.
A1000 Controller—Empty SIMM slots
FIGURE 3-9
5. Remove the SIMMs and set them on an antistatic mat.
Remove the SIMMs from front to back. Press the small latch on each side of the
SIMM that releases it from the slot (
a. Remove first two SIMMs from slot D and slot C (
aside.
These are 8 Mbyte SIMMs. You will use these SIMMs later.
b. Remove the SIMMs from slot B and slot A (
These are the 4 Mbyte SIMMs which you can save for use in other hardware.
4 Mbyte SIMM (ICs on front side only)
8 Mbyte SIMM (ICs on both sides)
SIMMs
FIGURE 3-10
6. Replace the 8 Mbyte SIMMs into slot A and slot B (
The SIMM is keyed and will fit only one way (notch in lower left corner)
(
).
FIGURE 3-10
Slot A
Slot B
Slot C
Slot D
).
FIGURE 3-10
FIGURE 3-10
FIGURE 3-9
32 Mbyte SIMM (upgrade only)
FIGURE 3-9
Chapter 3 Removing and Replacing Components
) and set them
).
).
31