Care & Cleaning
Humidifying fi lter replacement
If the humidifying filter lamp lights or flashes
1
Remove the front panel and water tank.
2
Pull out the humidifying tray and remove
the waterwheel and humidifying fi lter.
3
Remove the shaft that locks the
humidifying fi lter and waterwheel.
Turn the shaft to
the left.
4
Remove the humidifying fi lter from the
waterwheel, and attach a new fi lter.
Humidifying filter
Waterwheel
• uck the humidifying fi lter underneath the tabs (6 locations)
T
on the waterwheel so that it does not stick out from the
waterwheel.
Tuck the filter
under the tabs to
hold it in place.
Humidifying fi lter replacement
For replacement humidifying fi lters, contact the service shop. (See the ATTENTION on page 38.)
Dispose of used humidifying fi lters as noncombustible waste. (Material: Polyester, rayon)
37
(About every 2 years [2 seasons])
Using the unit without replacing the
humidifying fi lter causes mildew, foul
odors and humidifi cation loss.
Replace
Page 29.
Page 35.
Pull the shaft out.
Do not discard the waterwheel.
Tab
Before performing maintenance, stop the
unit and unplug the power supply cord.
5
Restore the shaft as before.
Restore the shaft.
Turn the shaft to
the right.
6
Restore the humidifying tray.
7
Restore the water tank and front panel.
8
Plug the power supply cord in.
9
Press and hold the humidifying fi lter reset
button at the top of the unit for 2 seconds.
(A short beep sound is emitted and the humidifying fi lter
lamp goes out.)
After replacing the humidifying fi lter, the humidifying fi lter
lamp does not go out unless the fi lter reset button is
pressed and held for 2 seconds.
WARNING