Daikin MCK75JVM-K Operation Manual page 35

Ururu air purifier floor standing type
Hide thumbs Also See for MCK75JVM-K:
Table of Contents

Advertisement

UNIT1
(Plasma ionizer)
(1) Ionizing frame
(3) Opposing pole
plates
(2) Ionized wire (Rear)
UNIT2
(4) Streamer unit
Open the front panel and pull out the
streamer unit.
Wear rubber
gloves.
(For details, see (4)
in the below figure.)
Reattach the streamer unit as before.
(2)
Ionized wire (8 locations)
Remove dirt from ionized wires and surrounding plastic parts
with a soft piece of cloth.
Wear rubber
gloves.
UNIT2
(Streamer unit)
(4) Streamer unit
Do not remove the screws from the ionizing frame or streamer unit.
This may lead to damage.
Clean UNIT1 and UNIT2 somewhere that can be wet such as in a shower room or kitchen sink.
For stubborn dirt, soak UNIT1 and UNIT2 in lukewarm or plain water in which neutral liquid
detergent (i.e., kitchen cleaner, etc.) has been dissolved.
Use the amount of neutral liquid detergent indicated in the cleaner's instructions.
Wipe
Do not use powdered, alkaline or acidic cleaners, and do not rub with hard bristle brushes, etc.
Abusive handling may lead to deformation and damage.
Do not touch the needles inside
Deodorizing capacity diminishes if the needles are deformed.
If cleaner remains on UNITS 1 or 2, the "UNIT1" and "UNIT2" lamps do not go out after cleaning,
therefore rinse off the cleaner well.
Do not leave any lint from cleaning cloths behind. Lint may lead to malfunction.
Plastic parts may deform or discolor if exposed to direct sunlight.
If water remains on UNITS 1 or 2, even in small quantities, the "UNIT1" and "UNIT2" lamps do not
go out after cleaning, therefore dry thoroughly in a shade.
Clean the ionized wires
without dislodging them
from the V-groove.
*Wipe ionized wires gently.
Pulling on them forcefully may
cause them to snap.
CAUTION
There are ionized wires to the rear of the opposite pole plates. Be
careful not to snap these wires when removing and attaching the
units.
If the unit is run with broken ionized wires, the "UNIT1" lamp
lights. While the lamp is lit, dust collecting capacity is low.
If the ionized wires are accidentally snapped, they need
replacing, therefore contact the service shop. (Do not replace
the wires yourself.)
Notes
UNIT2
(streamer unit).
(4)
Streamer unit
Remove dirt from plastic parts (
swab or soft piece of cloth.
Do not remove the screws.
Wear rubber
gloves.
Cotton
swab
: Plastic parts
) in internal areas with a cotton
Do not touch
the needles.
*Do not touch the needles (2 locations).
Deodorizing capacity diminishes if the needles
are deformed.
34