Daikin MCK75JVM-K Operation Manual page 33

Ururu air purifier floor standing type
Hide thumbs Also See for MCK75JVM-K:
Table of Contents

Advertisement

UNIT1 (Plasma ionizer) removing and attaching
CAUTION
Wear
rubber gloves to remove and attach the opposite pole plates. Hands can be cut on the opposite pole plates and ionized wires.
Remove
1
Remove the front panel.
2
Remove the water tank.
3
Remove the UNIT1.
Holding the UNIT1 by the handle, pull the UNIT1 upwards
and out of the unit.
Handle
(1)
Pull
UNIT1
4
Remove the opposite pole plates on the
backside of UNIT1.
Pinching together the white and green knobs (2 sets on
left and right), lift the opposite pole plates up and out.
Wear rubber
Opposing pole
gloves.
plates
There are
ionized wires inside,
therefore be careful
that they do not catch
on anything.
Ionized wire
Page 29.
Page 29.
(2)
Up
Pinching the sets of
knobs on the left and right at
the same time makes it easier
to remove the opposite
pole plates.
Knob
Knob
Ionizing frame
(green)
(white)
Attach
1
Attach the opposing pole plates.
(1) Fit the opposite pole plates over the knobs (2 sets on left
and right) on the ionizing frame.
The opposite pole plates have no required right and left
direction and can be attached either side of ionizing
frame. Attach them so that the arrow is visible.
Wear rubber
gloves.
Ionizing frame
(2) Insert securely until it clicks.
(3) Attach another side of the opposing pole plate.
2
Restore the UNIT1
water tank and front panel.
Arrow
Knob (white)
, pre-fi lter,
Page 31.
Page 29.
32

Hide quick links:

Advertisement

Table of Contents
loading