Sharp MX-FXX1 Service Manual page 36

Digital full color multifunctional system option facsimile expansion kit
Hide thumbs Also See for MX-FXX1:
Table of Contents

Advertisement

SW
Bit
Item
No.
No.
24
6
Scope of line sound
monitor
7-8
Volume setting of call
sound (large)
25
1-2
Volume setting of call
sound (medium)
3-4
Volume setting of call
sound (small)
5-6
Volume setting of line
monitor sound (large)
7-8
Volume setting of line
monitor sound
(medium)
26
1-2
Volume setting of line
monitor sound (small)
3
Not used
4
Remote changeover
permitted
5-7
Setting of call time (TO
timer setting) in
automatic transmission
8
External telephone
setting when no sound
is set
SW selection and function
Setting to determine the scope of monitoring when the line monitor
function is used
When "Until NSF signal send/receive" is set, monitoring is conducted
until the DCS or NSF signal is received. When "All" is set, everything is
monitored until the line is disconnected.
"0": Until NSF signal send/receive
"1": All
Setting of line monitor sound ON/OFF is done by a separate SW.
This sets the large (system setting) volume level of the call sound
outputted from the speaker. This includes volume of BZ-related sounds
(communication completion sound, communication error sound).
"00": Volume level 9
"01": Volume level 11
"10": Volume level 13
"11": Volume level 15
This sets the medium (system setting) volume level of the call sound
outputted from the speaker. This includes volume of BZ-related
(communication completion sound, communication error sound) and
on-hook sounds.
"00": Volume level 3
"01": Volume level 5
"10": Volume level 7
"11": Volume level 9
This sets the small (system setting) volume level of the call sound
outputted from the speaker. This includes volume of BZ-related
(communication completion sound, communication error sound) and
on-hook sounds.
"00": Volume level 0 (no sound)
"01": Volume level 1
"10": Volume level 2
"11": Volume level 3
This sets the large (system setting) volume level of the line monitor
sound outputted from the speaker.
"00": Volume level 9
"01": Volume level 11
"10": Volume level 13
"11": Volume level 15
This sets the medium (system setting) volume level of the line monitor
sound outputted from the speaker.
"00": Volume level 5
"01": Volume level 7
"10": Volume level 9
"11": Volume level11
This sets the small (system setting) volume level of the line monitor
sound outputted from the speaker.
"00": Volume level 1
"01": Volume level 3
"10": Volume level 5
"11": Volume level 7
Setting to determine whether to make only call arrival by remote
changeover from an external telephone valid or to make both call
transmission and arrival valid.
"0": Only call arrival
"1": Call transmission and arrival
Setting to determine how many seconds to call when the other party
doesn't respond at times of automatic transmission.
Setting can be made over the range of 30 seconds to 60 seconds in 15-
second increments by binary inputting N ((15 seconds x N) + 30
seconds).
The initial value is reverted to if a value outside of the setting range is
set.
Setting to determine whether or not to use external telephone when no
sound is set.
When the no sound priority setting is made, reception operation is
soundless but communications cannot be sent to and from an external
telephone.
When the external telephone priority setting is made, communications
can be sent to and from an external telephone, but reception operation
sounds once.
"0": External telephone priority
"1": No sound priority
MX-FXX1 SIMULATIONS, FAX SOFTWARE SWITCH 5 – 27
Initial value
0
Until NSF signal send/
receive
1
Volume level 13
0
0
Volume level 5
1
1
Volume level 2
0
1
Volume level 15
1
1
Volume level 11
1
1
Volume level 7
1
0
0
Only call arrival
0
45 seconds
0
1
0
External telephone priority
System
settings

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents