B.2 Parameter Table
u

A: Initialization Parameters

The A parameter group creates the operating environment for the drive. This includes the parameter Access Level, and
Password.
No.
Name
Selects which parameters are accessible via the digital operator.
A1-01
Access Level
0: Operation only
<22>
Selection
2: Advanced Access Level
Resets all parameters to factory default settings. (Initializes the
drive then returns A1-03 to 0)
A1-03 Initialize
0: No Initialize
Parameters
2220: 2-Wire Initialization
3330: 3-Wire Initialization
A1-04 Password 1
When the value set into A1-04 does not match the value set into
A1-05, parameters A1-01 and A1-03 cannot be changed.
A1-05 Password 2
<22> Parameter can be changed during run.
u

b: Application

Application parameters configure the Run Command Source, DC Injection Braking, and other application-related settings.
No.
Name
Selects the frequency reference input source.
Frequency
0: Operator - Digital preset speed d1-01 to d1-08
b1-01
Reference
1: Terminals - Analog input terminal A1
Selection
2: MEMOBUS/Modbus communications (option)
3: Potentiometer (option)
Selects the run command input source.
Run Command
0: Operator - RUN and STOP keys on the digital operator
b1-02
Selection
1: Digital input terminals
2: MEMOBUS/Modbus communications (option)
Selects the stopping method when the run command is removed.
b1-03 Stopping Method
0: Ramp to Stop
Selection
1: Coast to Stop
Permits or prohibits reverse operation.
b1-04 Reverse Operation
0: Reverse enabled.
Selection
1: Reverse disabled.
Determines the operation when the Run command source is
switched from LOCAL to REMOTE or between REMOTE and
b1-07 LOCAL/REMOTE
MEMOBUS/Modbus communication.
Run Selection
0: External Run command has to be cycled at the new source to be
activated.
1: External Run command at new source is accepted immediately.
Run Command
0: Run command accepted only in the operation menu.
Selection while in
b1-08
1: Run command accepted in all menus.
Programming
2: Prohibit entering Programming Mode during Run
Mode
Sets the phase order for drive output terminals U/T1, V/T2 and W/
b1-14 Phase Order
T3.
Selection
0 : Standard
1 : Switch phase order
Determines the operation when a Run command is active at power
b1-17 Run Command at
up of the drive.
Power Up
0: Run command not issued, needs to be cycled
1: Run command issued, motor operation start
b2-02 DC Injection
Sets the DC Injection Braking current as a percentage of the drive
Braking Current
rated current.
SIEP C710606 33A OYMC AC Drive – J1000 User Manual
Description
A1: Initialization Parameters
Use A1 parameters to configure the basic environment for drive operation.
Description
b1: Operation Mode Selection
Use b1 parameters to configure the operation mode.
b2: DC Injection Braking
Use b2 parameters to configure DC Injection Braking operation
B.2 Parameter Table
Range
Def.
Mode
0, 2
2
O
0 to 3330
0
O
U2 monitors are not reset when performing
initialization.
0 to 9999
0
O
0 to 9999
0
O
This parameter is hidden from view. To access
A1-05, first display A1-04. Then press the STOP
key while holding down the up arrow key.
Parameter A1-05 will appear.
Range
Def.
Mode
0 to 3
1
S
0 to 2
1
S
0, 1
0
S
0, 1
0
O
0, 1
0
O
0 to 2
0
O
0, 1
0
O
0, 1
0
O
0 to 75
50%
O
Addr.
Pg.
Hex
101
103
70
104
70
105
70
Addr.
Pg.
Hex
180
72
181
73
182
74
183
75
186
75
187
75
1C3
75
1C6
76
B
18A
76
171

Advertisement

Table of Contents
loading

This manual is also suitable for:

Jza j1000

Table of Contents