Local Administrative Options Using The Telephone Dialpad - Avaya one-X 9600 Series Administrator's Manual

Deskphone release 6.0
Hide thumbs Also See for one-X 9600 Series:
Table of Contents

Advertisement

Administering Telephone Options
Table 15: Impact of TLVs Received by 9600 Series IP Deskphones on System Parameter
Values (continued)
System
Parameter Name

Local Administrative Options Using the Telephone Dialpad

The Avaya one-X™ Deskphone Edition for 9600 IP Telephones Installation and Maintenance
Guide details how to use Craft local procedures at the telephone for administration. The local
procedures you might use most often as an administrator are:
CLEAR - Remove all administered values, user-specified data, option settings, etc. and
return a telephone to its initial "out of the box" default values.
DEBUG - Enable or disable debug mode for the button module serial port.
GROUP - Set the group identifier on a per-phone basis.
INT - Set or change the interface control value(s) of PHY1STAT and/or PHY2STAT.
RESET - Reset the telephone to default values including any values administered through
local procedures, and values previously downloaded using DHCP or a settings file.
RESTART - Restart the telephone in response to an error condition, including the option to
reset parameter values.
VIEW - Review the 9600 IP Telephone system parameters to verify current values and file
versions.
INT - Secondary Ethernet (Hub) Interface Enable/Disable - Enable or disable the
secondary Ethernet hub locally.
112 9600 Series IP Deskphone Administrator Guide Release 6.0
TLV
Name
Proprietary - PoE
Conservation TLV
Extended
Power-Via-MDI
Impact
This proprietary TLV can initiate a power
conservation mode. The telephones that support
this will turn on/off the telephone backlight and the
backlight of an attached Button Module in response
to this TLV. Exception: the 9670G display backlight
is put into low-power mode rather than being turned
off.
Power conservation mode will be enabled if the
received binary Power Source value is 10, and
power conservation mode will be disabled if the
received binary Power Source value is not 10.
Power conservation mode is enabled even if the
telephone is not powered over Ethernet because
the telephone sends information about the power
source that it is using in a TIA LLDP MED Extended
Power-Via-MDI TLV; it is assumed that the power
management system intends to conserve local
power as well.

Hide quick links: