Fault
The power tool doesn't start.
No hammering action.
The power tool doesn't start
and the LED lights red.
The power tool doesn't start
and the LED blinks red.
The power tool cuts out while
running and the LED lights
red.
The power tool doesn't start
and the indicator lamp blinks
yellow.
The power tool doesn't achieve
full power.
The chisel can't be released
from the chuck.
NOTE
If the fault cannot be eliminated by the measures listed above, have the power tool checked by Hilti Service.

10. Disposal

Most of the materials from which Hilti power tools or appliances are manufactured can be recycled. The
materials must be correctly separated before they can be recycled. In many countries, Hilti has already made
arrangements for taking back your old power tools or appliances for recycling. Please ask your Hilti customer
service department or Hilti representative for further information.
Possible cause
Generator with sleep mode.
The power tool is too cold.
A fault has occurred in the power
tool.
A fault has occurred in the power
tool.
The voltage provided by the electric
supply is too high.
The overheating prevention cut-out
has been activated.
The power tool has not been
unlocked (power tools with optional
theft protection system).
Reduced power activated (only
TE 1000 AVR).
The extension cord is too long or its
gauge is inadequate.
The voltage provided by the electric
supply is too low.
The chuck is not pulled back fully.
Remedy
Apply a load to the generator by
connecting another appliance (e.g.
a lamp). Subsequently switch the
power tool off and on again.
Allow the power tool to warm
up to the minimum operating
temperature.
See section: 7.2.2 Chiseling
If necessary, the power tool should
be repaired by Hilti Service.
If necessary, the power tool should
be repaired by Hilti Service.
Use a different power outlet.
Check the electric supply.
Allow the power tool to cool down.
Clean the ventilation slots.
Use the TPS key to unlock the power
tool.
Press the power selector switch
(observe the power level indicator).
Switch the power tool off and on
again.
Use an extension cord of an
approved length and / or of
adequate gauge.
Connect the power tool to a different
power source.
Pull the chuck back as far as it will
go and remove the insert tool.