Default Values Of The E-Plex Lock Programmable Parameters; Configuring The Lock; General Procedure For Pushbutton Programming - Kaba EX3600 Operation Manual

E-plex card based lock series
Table of Contents

Advertisement

• Program the Lock for the Duration of Passage Mode
• Program the Lock for Tamper Time Settings
• Program the Lock for Buzzer Volume
• Add Access Credentials as desired
Note: A credential can be either Card only access or PIN followed by Card access for reg-
ular Access users and Manager users. Or, it can be PIN only access for Service users. In
LearnLok
mode only, the Master credential is always PIN only mode and it is always 8
TM
digits in length.
Default values of the E-Plex
Parameters
Date (MM/DD/YY)
Time (HH:MM)
Lock state
Passage mode open time limit
Passage mode
Lockout mode
Unlock time
Buzzer volume control
Tamper shutdown time
Tamper attempt count
Access code length
Latch Holdback Mode
Swingbolt Privilege
Privacy Privilege
BHMA Lock Function
Master combination
Access credential
Credential status
M-Unit user's combination
M-Unit user's status

Configuring the Lock

General Procedure for Pushbutton Programming

1. The pages that follow provide step-by-step instructions for programming the
E-Plex Lock.
2. The general procedure for all programming functions is as follows:
a. Put the lock in Programming Mode by pressing # Master Credential #
b. Use the Summary of Commands Table in the appendix section of this guide to
enter the three digit command sequence (Command Code + Function Code), fol-
lowed by #.
c. Enter the appropriate numbers as required.
d. Press # to end Programming Mode.
e. Once the lock is in programming mode, multiple command sequences can be
entered without having to repeat the # master credential #. However, if there
is no activity for 15 seconds at the keypad, the lock will automatically exit from
programming mode.
Lock programmable parameters
®
Factory Default Values
01/01/00
00:00
Unprogrammed
9 hours
De-activated/Disabled
Disabled
2 seconds
Low (=1)
30 seconds
4 attempts
4 digits
Disabled (E-3xxx only)
Disabled (E-3xxx only)
Disabled (E-5xxx only)
Entry (E5xxx); Latch (E3xxx)
12345678 (8 digits)
None
Activated
None
Disabled
(if desired)
(*used with software only)
(*used with software only)