1. Master and Manager Credentials can do two different things:
• Open the door by entering the Access Credential without # signs.
• Put the lock into LearnLok
before and after their Access Credential.
2. Each user - the Manager user, the Access user or the Access user occupies one of
the available 300 locations in the user table of the lock's memory, from 001 through
300.
3. By default, the Master user occupies user table location 000 which is
reserved for the Master.
4. The Master and Manager users have a 15-second period to enter the
entire programming key sequence, and 5 seconds between pressing
each pushbutton number. If they pause longer than 5 seconds between
pressing each pushbutton number. If they pause longer than 5 seconds
between each pushbutton pressed, or exceed the 15-second period to
enter the total programming sequence, the lock:
• aborts the current programming sequence
• automatically exits the programming state
• sends the user a 'Keypad Timeout' feedback message (LEDs and buzzer)
Note: Correct errors during a command sequence . If an invalid entry occurs, recover
from the mistake by entering the ( * ) key, which will clear all entries made from the
beginning of the current command sequence, and will reset the 15-second time limit for
entering the code. In this case, you still have 15 seconds from the first number entered
to enter the whole command code sequence.
USER LEVELS
Five different classifications of users can perform various operations at the lock.
Master User - The Master User is the top-level manager who performs the initial lock
setup activities, can program all lock functions and has complete access to the locks any-
time without any restrictions.
Manager - A Manager can open the lock and can also program all lock functions except:
• defining the Access User Code length
• modifying master user PIN
• changing date and time
• resetting lock to selected default values
• activating/de-activating global lockout mode
• adding / deleting / enabling / disabling another Manager User. The number of
Managers is limited only by available user table space - 300 maximum.
Access User - A regular Access User has the ability to only open the lock. The number
of Access Users is limited only by the available user table - 300 maximum.
Service User - A Service user can open the lock either one time only, or from 1 through 96
hours, or can access the lock with no expiry, depending on how s/he is enrolled in the lock.
When in non expiry mode, the period of Service's user's access time starts on the first user
of his PIN. Each Service User PIN is automatically deleted from the lock's memory after its
period of time expires. The number of service users is limited only by the available user
table space - 300 maximum.