Procedure 12B - Activate / De-Activate Passage Mode; Procedure 13B - De-Activate Access User Credentials - Kaba EX3600 Operation Manual

E-plex card based lock series
Table of Contents

Advertisement

2. Enter Command 398# to re-activate all Access and Service users.
Enter a last # to indicate the end of programming.
Example of Complete Entry:
398# # .

PROCEDURE 12B - ACTIVATE / DE-ACTIVATE PASSAGE MODE

Let's assume that you had already programmed a default duration for a door to remain in
Passage Mode as per Procedure 5A, Program the Duration of the Passage Mode
Period, on page 9. This procedure 12B shows you how to activate the Passage Mode so
that the lock is in free passage and no credential is required to gain entry during the
duration set in Procedure 5A.
If your set passage duration is 6 hours for example, and you activate the Passage Mode
at 1:00, it will automatically relock at 7:00. The lock can be taken in and out of Passage
Mode multiple times during the six hour period but it will still automatically re-lock after
six hours from the original starting period. This ensures that a lock will never remain in
free Passage Mode beyond the programmed time period of 1 to 24 hours.
Required User Level: Master, Manager
1. Put the lock into "LearnLok
(or Manager credential) #
2. Enter Command 399# to re-activate all Access and Service users.
3. Enter 1# to activate Passage Mode (or, 0# to de-activate Passage Mode).
4. Example of Complete Entry to activate Passage Mode
399#1# #.
5. Example of Complete Entry to de-activate Passage Mode if free passage was still
active: 399#0# #.

PROCEDURE 13B - DE-ACTIVATE ACCESS USER CREDENTIALS

An Access user's credential can be de-activated (rather than deleted) if
required, for example during her/his vacation temporarily; or return, can then
be easily re-activated as described in Procedure 8B.
Required User Level: Master, Manager
1. Put the lock into "LearnLok
(or Manager credential) #
2. Enter Command 400# to de-activate an Access user's credential; you do not need
this person's PIN and/or card to do this.
3. Enter this user's ID location (001 through 300); we will use the ID location 023 in
this example.
Enter a last # to indicate the end of programming.
Example of Complete Entry for user ID=023:
400#023# #.
You have now temporarily de-activated this Access user's credential.