Selector
No.
Starting point of training check
1
(TCF)
2
Allowable training error rate
3
4
Decoding error rate for
transmission of RTN
5
Issue of RTN at the occurrence
6
of a pagination error
7
Not used.
8
Limitation of attenuation level
Selector 1:
Starting point of training check (TCF)
At the training phase of receiving operation, the called station detects for 1.0 second a train-
ing check (TCF) command, a series of zeros which is sent from the calling station for 1.5
seconds to verify training and give the first indication of the acceptability of the line.
This selector sets the starting point from which the called station should start counting those
zeros. If this selector is set to "0," the called station starts counting zeros 100 ms after the
head of a series of zeros is detected.
If it is set to "1," the called station starts counting zeros upon detection of 10-ms successive
zeros 50 ms after the head of a series of zeros is detected. In this case, if the detection of
10-ms successive zeros is too late, the data counting period will become less than 1.0 sec-
ond, making the called station judge the line condition unacceptable.
Selectors 2 and 3: Allowable training error rate
The called station checks a series of zeros gathered in training (as described in Selector 1)
according to the allowable training error rate set by these selectors. If the called station
judges the line condition to be accepted, it responds with CFR; if not, it responds with FTT.
Selectors 4 and 5: Decoding error rate for transmission of RTN
The facsimile equipment checks the actual decoding errors and then transmits an RTN ac-
cording to the decoding error rate (Number of lines containing an error per page ÷ Total num-
ber of lines per page) set by these selectors.
Selector 6:
Issue of RTN at the occurrence of a pagination error
If this selector is set to "0," the facsimile equipment transmits an RTN when a pagination er-
ror occurs due to recording lag relative to receiving.
Selector 8:
Limitation of attenuation level
Setting this selector to "0" limits the transmitting level of the modem to 10 dB.
This setting has priority over the settings selected by WSW02 (selectors 5 through 8) and
WSW13 (selectors 5 through 8).
WSW23
(Communications setting)
Function
V – 35
Setting and Specifications
0: From the head of a series of zeros
1: From any arbitrary point
No. 2
3
0
0
:
0%
0
1
:
0.5%
1
0
:
1%
1
1
:
2%
No. 4
5
0
0
:
16%
0
1
:
14%
1
0
:
10%
1
1
:
8%
0: YES
1: NO
0: YES
1: NO