WIRING

POWER WIRING

This operator can be wired for either 120 Vac or 240 Vac or a solar
panel (not provided). Follow the directions according to your application.
For dual gate applications, power will have to be connected to each
operator. Main power supply and control wiring MUST be run in
separate conduits.
NOTE: If using an external receiver use shielded wire for the connections and
mount the receiver away from the operator to avoid interference with the operator.
240 VAC ONLY
If using the 240 Vac option a heater cannot be used. The accessory outlet is disabled
and cannot be used with the 240 Vac option.
1
Remove the outlet housing from the electrical box by removing the screws (2).
2
Pull the outlet housing out and locate the power wiring connector on the EMI
board.
3
Unplug the power wiring connector from the 120 Vac socket (factory default
location) and plug it into the 240 Vac socket.
4
Replace the outlet housing by securing with the screws. The operator is now set
for 240 Vac operation.
120 VAC AND 240 VAC
1
Turn off the AC power from the main power source circuit breaker.
2
Run the AC power wires to the junction box on the operator.
3
Remove the junction box cover.
4
Connect the green wire to the earth ground rod and AC ground using a wire
nut. NOTE: The earth ground rod can be grounded to the chassis.
5
Connect the white wire to NEUTRAL using a wire nut.
6
Connect the black wire to HOT using a wire nut.
7
Replace the junction box cover. Ensure the wires are not pinched.
AMERICAN WIRE
MAXIMUM WIRE
GAUGE (AWG)
LENGTH (120 VAC)
14
12
10
8
6
4
NOTE: Use copper conductors ONLY.
Outlet Housing
EMI Board
240 Vac Socket
15
POWER WIRING
MAXIMUM WIRE
LENGTH (240 VAC)
130 feet
260 feet
205 feet
410 feet
325 feet
650 feet
520 feet
1040 feet
825 feet
1650 feet
1312 feet
2624 feet
Power Wiring Connector
(120 Vac Socket, factory default)