Control Board Leds Continued - Chamberlain LiftMaster Elite CSL24VH Installation Manual

Liftmaster elite series vehicular slide gate operator
Hide thumbs Also See for LiftMaster Elite CSL24VH:
Table of Contents

Advertisement

TROUBLESHOOTING

CONTROL BOARD LEDS CONTINUED...

YELLOW DIAGNOSTIC LED
# BLINKS
MEANING
2 BLINKS
ID resistor failure
3 BLINKS
Exceeded Maximum
Run Timer
RPM (obstruction)
5 BLINKS
6 BLINKS
Current (obstruction)
7 BLINKS
Position failure
12 BLINKS
Loop Error
STATUS LEDS
INPUT
OFF
POWER
ON
BATT
OFF
CHARGING
ON
FAST BLINK (2 blinks
per second)
SLOW BLINK (1 blink
every 2 seconds)
TIMER
OFF
ON
MEDIUM BLINK (1
blink per second)
FAST BLINK (2 blinks
per second)
FASTEST BLINK (8
blinks per second)
GATE
OFF
MOVING
ON
MEDIUM BLINK (1
blink per second)
FASTEST BLINK (8
blinks per second)
BATT LOW
OFF
ON
MEDIUM BLINK (1
blink per second)
FAST BLINK (2 blinks
per second)
FASTEST BLINK (8
blinks per second)
ACC PWR
OFF
OVLD
ON
DIAGNOSTIC CODES LEDS
CORRECTION
Check ID resistor wiring, clear limit
settings and reset limits
Check gate travel, if necessary adjust
force setting
Check for obstruction, if necessary adjust
force setting
Check for obstruction, if necessary adjust
force setting
Check gate travel, clear limit settings
and reset limits
One of the loops is in error. Refer to the
loop detector to determine the error.
OFF state
AC charger or Solar power available
Not charging
Trickle charge
High current charge
Medium charge
The timer is disabled
The timer is enabled
The timer is running
The timer is paused
The timer is cancelled
The gate is stopped
The gate is opening or closing
Operator is in E1 (single entrapment)
The operator is in E2 (double entrapment)
No battery error
Battery low
Battery critically low
Battery disconnected error (seen in solar
application, motion is inhibited)
Battery over voltage/over current error
OFF state
Accessory overload protector opened
RED DIAGNOSTIC LED
# BLINKS
MEANING
2 BLINKS
Current Sense
3 BLINKS
FET Failure
RAM Failure
4 BLINKS
5 BLINKS
Flash Memory
Failure
6 BLINKS
EEPROM Failure
7 BLINKS
Watchdog Failure
8 BLINKS
Brownout
9 BLINKS
Fail
Software Failure
10-14 BLINKS
INPUT LEDS
OPEN INPUT
OFF
ON
BLINK
CLOSE INPUT
OFF
ON
BLINK
STOP INPUT
OFF
ON
BLINK
FIRE DEPT
OFF
INPUT
ON
BLINK
OPEN SAFETY
OFF
INPUT
ON
BLINK
CLOSE SAFETY
OFF
INPUT
ON
BLINK
35
CONTROL BOARD LEDS
CORRECTION
Motor control circuit fault, replace
control board
Motor control circuit fault, replace
control board
Memory failure, replace control board
Memory failure, replace control board
Memory failure, replace control board
Controller failure, replace control board
Check power harness or line voltage
Control Board failure
Cycle power to the control board. If
continues replace control board.
Input inactive
Input active
Input active on other operator
Input inactive
Input active
Input active on other operator
Input inactive
Input active
Input active on other operator
Input inactive
Input active
Input active on other operator
Input inactive
Input active
Input active on other operator
Input inactive
Input active
Input active on other operator