Additional Features; Control Board Overview - Chamberlain LiftMaster Elite CSL24VH Installation Manual

Liftmaster elite series vehicular slide gate operator
Hide thumbs Also See for LiftMaster Elite CSL24VH:
Table of Contents

Advertisement

ADDITIONAL FEATURES

CONTROL BOARD OVERVIEW

1
The SET OPEN button sets the OPEN limit. See Adjust Limits section.
SET OPEN Button:
2
The SET CLOSE button sets the CLOSE limit. See Adjust Limits section.
SET CLOSE Button:
3
The MOVE GATE buttons will either open or close the gate when the operator is in Limit setting mode. See Adjust Limits section.
MOVE GATE Buttons:
4
BIPART DELAY Switch:
5
LEARN RADIO Button:
6
TIMER-TO-CLOSE dial:
TTC is set to the OFF position, then the gate will remain open until the operator receives another command from a control. Rotate the TIMER-TO-CLOSE dial to the desired
setting. The range is 0 to 180 seconds, 0 seconds is OFF.
NOTE: Any radio command, single button control, or CLOSE command on the control board prior to the TTC expiring will close the gate. The TTC is reset by any signals
from the open controls, loops, close edges, and close photoelectric sensors (IR's).
7
REVERSAL FORCE dial:
8
The TEST BUTTONS will operate the gate (OPEN, STOP and CLOSE).
TEST BUTTONS:
9
The STATUS LEDs are diagnostic codes for the operator. See Status LED Chart in the Troubleshooting section.
STATUS LEDs:
10
To check the firmware version for the main board:
Firmware Version:
1. Locate the yellow diagnostic LED on the main control board.
2. Disconnect AC/DC power to the main control board for 15 seconds.
3. Connect power. The yellow diagnostic LED will flash rapidly, then stop, then flash the version number, then stop, then flash the revision number (for example: For
version 5.1 the LED will flash rapidly, stop, flash 5 times, stop, then flash once).
The LOCK/BIPART DELAY switch is used only for dual gates. See Bipart Delay section.
The LEARN RADIO button is for programming remote controls and the network.
The TIMER-TO-CLOSE (TTC) dial can be set to automatically close the gate after a specified time period. The TTC is factory set to OFF. If the
The REVERSAL FORCE dial adjusts the force. See Force Adjustment section.
1
9
2
4
5
6
7
3
26
CONTROL BOARD OVERVIEW
8
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Liftmaster elite csl24v

Table of Contents