17. Service mode

To access service mode, you need to wake up LOGBOX SD from sleep mode. You will
type CTRL+BREAK on your serial line once. If there is no response after about 5
seconds, try again (data logger is serial line sensitive only for about 50% of time due
to low power operation). Then, your communication software must be set for
communication speed 115200bps, as service mode is accessible with this speed
only. You will receive following answer from the LOGBOX SD:
LOGBOX SD (C) Physicus. Version T2.07.217 Jun 19 2007
Service mode started.
>
Now all setup commands are available.
Summary of setup commands:
? – displays current setup
?
LOGBOX SD (C) Physicus. Version T2.07.217 Jun 19 2007
LogMode: CIRCULAR
LogAddress: 91336
CircEndAddress: 131040
LogInterval: 5 minutes
SdWrittingInterval: 10 minutes
SdFileClose: 24 hours
Delay: 0
BaudRate: 115200
Temperature[mV]: 1083.8, AVcc[mV]: 3106.4
ReferenceVoltage: 2500.000 mV
DateTime: 2005-03-11 11:22:56
OK
T – time setup with syntax HH MM SS (HH-hour, MM-minute, SS-second)
T
Enter HH MM SS
19 09 10
You've entered 19:09:10
<Y> = set, else = quit
Y
SET.