. S201
-1, 2 (CB CONT)
Selects the color bar to be output from the ANALOG
COMPOSITE (VBS) generator.
Setting switches
S201-1
OFF
ON
S201-2
OFF
ON
Factory setting : S201-1 → ON
S201-2 → OFF
-3, 4
Not used.
Factory setting : OFF
. S401 (G/Y SYNC SEL)
Selects whether SYNC is added or not to the G/Y signal
of SD.
ON : Added
OFF : Not added
Factory setting : ON
. S402 (SETUP SEL)
Selects whether SETUP is added or not to the VBS
signal of SD when S427-1 on the AT-149 board is set to
OFF (NTSC).
ON : Added
OFF : Not added
Factory setting: OFF
HDCU-950 IMM
Color bar
SD COMPONENT-CB
SD COMPOSITE-CB
SMPTE-CB
EIAJ/EBU
1-6. Setting of Switches on Boards
1-21 (E)