1032-1042 Codes - Canon iPF9000S Troubleshooting Manual

Ipf5000, ipf700, ipf8000, ipf800, ipf650/750 series
Hide thumbs Also See for iPF9000S:
Table of Contents

Advertisement

Panel display
Code
(last 4
Large LCD
digits)
1032
GARO W1223
1034
GARO W1225
1035
GARO W1231
1036
GARO W1232
1037
GARO W1233
1038
GARO W1234
1039
GARO W1235
103A
GARO W1226
1040
GL2: W0501
The memory is full.
1041
GL2: W0502
The parameter is
out
of range.
1042
Small
Small
LCD 1
LCD 2
GARO
W1223
GARO
W1225
GARO
W1231
GARO
W1232
GARO
W1233
GARO
W1234
GARO
W1235
GARO
W1226
GL2:
W0501
GL2:W05
02
Explanation/Detection sequence
(Image mode) Required item missing
A character out of bounds has been
detected where a group or end parameter
character ought to exist, during Image mode
command decoding.
(Image mode)Other warning
A character other than <ESC> has been
detected right after the image mode analysis
module entered Image mode or when the
decoding of a single command ended.
(Setup mode)Unknown command
A command character string other than
RESET, SET, OPCMT0 and OPCMT2 has
been detected in a PJL command.
(Setup mode)Invalid parameter count
Too many or too few parameters have been
detected during Setup mode command
decoding.
(Setup mode) Required item missing
The exit parameter is missing in the
EnterGAROMode command and the
UniversalExitLanguage command used in
Setup mode.
(Setup mode)Data out of bounds
A character string that is not defined as an
environmental variable has been detected.
An unknown environmental variable has
been detected.
A character string that is not defined as an
environmental variable value has been
detected.
The value of an unknown environmental
variable has been detected.
(Setup mode) Other warning
A character string other than the @PJL
prefix has been detected while the analysis
module was idle.
(Image mode) Image processing table error
No image processing table is being
transmitted, a required image processing
table is unavailable, or an image processing
table contains a value out of bounds.
HP/GL2 error; Insufficient memory capacity
The size of drawing data exceeds the
processing capacity.
HP/GL2 error; invalid parameter
Data having an invalid number of types of
parameters that follow the command has
been detected.
HP/GL2 error; physical coordinate check
from logical coordinates
Invalid coordinates are included.
2-5
Chapter 2 Indexes by Case
Remedial Action
(★: Reference fault
isolation procedure
or tool)
①Retransmit.
②Check with a
different
interface
choice.
③Try by printing
other data.
④With RIP, print
from the print
driver.
Supplement: If
this error
occurs, the print
result would
appear blank.
①Reduce the size
of rendering
data.
②Replace with
HP RTL data for
manipulation
with On The Fly.
Verify the data
and fix it.
Verify the data
and fix it.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents