JAI TM-6710 Operation Manual page 32

High-speed progressive scanning ccd camera
Table of Contents

Advertisement

Page 26
Camera Timing Charts
Model: TM-6710/6710CL
Master Clock: 50.98_MHz, M= 19.62_ nsec
Pixel Clock:
3. External Reset Timing
External VD
B [0 H], (12 µsec)
Internal VD
F [3 H], (196.7 µsec)
FDV
Q [5 H], (328 µsec)
Digital Data
I [2 H], (131.2 µsec)
Analog Video
L [3 H], (98.39 µsec)
4. Async Reset Timing
VINIT Trigger
Q [1 H], (65.59 µsec)
Internal VD
U [3 H], (196.79 µsec)
FDV
Z [5 H], (0.328 ms)
Digital Data
W [0 H], (3 µsec)
Analog Video
ZZ [3 H], (49.2 µsec)
TM-6710/6710CL High-Speed Progressive Scanning CCD Camera
12.75_MHz, P= 78.46_ nsec
A [254 H], (16.66 msec)
C [4.5 H] (295 µsec)
D [249.5 H], (16.37 ms)
E [254 H], (16.66 ms)
G [5 H], (0.328 ms)
H [249 H], (16.33 ms)
J [7 H], (0.459 ms)
K [242 H], (15.87 ms)
M [18 H], (0.59 ms)
O [484 H], (15.87 ms)
N [3 H], (98.39 µsec)
Q: Internal VD shift = 1H + async shutter speed
R [4.5 H], (295.18 µsec)
S [249.5 H], (16.37 ms)
T [254 H], (16.66ms)
V [5 H], (0.328 ms)
H [249 H], (16.33ms)
X [7 H], (0.459 ms)
Y [237 H], (15.55 ms)
AA [18 H] (0.59 ms)
CC [484 H], (15.94 ms)
BB [3 H], (49.2 ms)
Operation Mode: 60 Frames/Second
Horizontal Frequency: 15.245_KHz
1H = 65.595_ µsec Digital
1H = 32.8_ µsec
P [6 H], (196.79 µsec)
Analog
Q [5 H], (0.328 ms)
Z [5 H] (0.328 ms)
DD [6 H], (98.4 µsec)

Advertisement