JAI TM-6710 Operation Manual page 28

High-speed progressive scanning ccd camera
Table of Contents

Advertisement

Page 22
Operation
RS-232C Control Commands Summary Table
TABLE 2.
1st CHAR
"S"
(Shutter)
"G"
(Gain)
"V"
(A/D Vref)
"W"
(Write)
"L"
(Load)
"R"
(Report)
"C"
(Clock)
"N"
(Partial Scan)
"O"
(Async sync out)
TM-6710/6710CL High-Speed Progressive Scanning CCD Camera
2nd CHAR
3rd CHAR
"M" (Manual)
"0" - "9" Mode
"A" (Async)
"0" - "8" Mode
"9" (Pulse width)
"M" (Main)
"00" - "FF"
"A" (Fine A CH)
"00" - "FF"
"B" (Fine B CH)
"00" - "FF"
"A" (CH1)
"00" - "FF"
"B" (CH2)
"00" - "FF"
"T" (Top)
"00" - "FF"
"L" (BTM/Vsub)
"00" - "FF"
"P" (Page)
"U" (User)
"S" (System)
"P" (Page)
"U" (User)
"S" (System)
"R" (Current)
"P" (Page)
"U" (User)
"S" (System)
"X" (Execute)
"D" (Date)
"0" (120Hz)
"1" (60Hz)
"0" (Normal)
"1" (200 lines)
"2" (100 lines)
"0" (Continuous)
"1" (One Shot)
Response
ACK
ACK
ACK
ACK
ACK
ACK
ACK
ACK
ACK
ACK
"0" - "6"
ACK
"A" - "D"
ACK
"A" - "D"
ACK
"0" - "6"
ACK
"A" - "D"
ACK
"A" - "D"
ACK
ACK
"0" - "6"
ACK
"A" - "D"
ACK
"A" - "D"
ACK
ACK
DATE
ACK
ACK
ACK
ACK
ACK
Functions
Manual shutter mode
Async shutter mode
Pulse width mode
Main CH Gain Control
CH1 Gain Fine Tuning
CH2 Gain Fine Tuning
CH1 Vref Fine Tuning
CH2 Vref Fine Tuning
Vtop voltage setting
Vbottom - Vsub setting
Write to P EPROM
Write to U EPROM
Write to S EPROM
Load from P EPROM
Load from U EPROM
Load from S EPROM
ACK + "RR"+12x2 bytes
ACK + "P"+{"9" - "F"}+ 12x2 bytes
ACK + "U"+{"9" - "F"}+ 5x2 bytes
ACK + "S"+{"9" - "F"}+ 5x2 bytes
Set camera with loaded data
Report program date
Using master clock
Using half of master clock
Normal scan
200 line scan
100 line scan
Continuous sync out in Async Mode.
One sync with on VINIT.

Advertisement