Comtech EF Data MBT-4000 Installation And Operation Manual page 56

Multi-band transceiver system
Hide thumbs Also See for MBT-4000:
Table of Contents

Advertisement

MBT-4000 Multi-Band Transceiver System
Remote Control
Command
Valid on
Parameter
(Instruction
Type
Code and
BDC, or
qualifier)
Concise Utility
N/A
MBT
Status
Set RTC
DAT=mmddyy
All
(Real-Time-
Clock) Date
Enable Aux
EAM=nm
MBT
Com
Fault Input
Monitoring
Operating
FRE=xxxxx.xxx BDC
RF Frequency
BUC
Retreive
N/A
All
Firmware
Number
Arguments
MBT,
for Command
(Note that all arguments are ASCII numeric codes – i.e.,
or Response
BUC
to Query
21 bytes
Query only.
alphanumeric
Used to query the utility status of the MBT-400 Base Unit,
response is comma delimited, where:
aaaa=Physical Address
bbbb=Remote Baud Rate
Example: <0001/CUS?
6 bytes,
Command or Query.
numeric
A command in the form mmddyy, where;
dd = day of the month, between 01 and 31
mm = month of the year, between 01 and 12
yy = year, between 00 and 96 (2000 to 2096)
Example: DAT=042503 would be April 24, 2003.
n=1 AUX
Command or Query.
COMM1
EAM controls monitoring of external fault logic inputs to Aux
2=AUX
Comm connectors (J8/J9 pin F). If enabled and external fault
COMM2
input is at Logic 1 ( > 2.6 vdc) a fault will be reported.
m=0
Note: The inputs may be driven by a contact closure relay.
(disabled), 1
(monitoring
They have an internal pull-up resistor (4.7k) to +5 vdc.
enabled)
Example: EAM=21
9 bytes,
Command or Query
numeric
Valid Operating RF frequency, in MHz.
For Ku BDCs:
FRE values: 10950-11700 MHz an LO of 10000 MHz is activated
FRE values: 11701-12250 MHz an LO of 10700 MHz is activated
FRE values: 12251-12750 MHz an LO of 11300 MHz is activated
Example: FRE=11300.000
Query only
Gets the Firmware Number of the unit.
Example: FRW=FW12001'cr''lf'
Description of Arguments
ASCII codes between 48 and 57)
>0001/CUS=aaaa,bbbb{cr}{lf}
A–12
Revision 4
MN/MBT4000.IOM
Response to
Query
Command
(Instruction
(Target to
Code and
Controller)
qualifier)
N/A
CUS?
DAT= (message OK)
DAT?
DAT? (received OK,
but invalid arguments
found)
DAT* (message OK,
but not permitted in
current mode)
EAM=(message OK)
EAM?n
EAM?(received OK,
but invalid arguments
found)
FRE=(message OK)
FRE?
FRE? (received OK,
but invalid arguments
found)
FRE* (message OK,
but not permitted in
current mode)
FRE! (command not
accepted by MBT-
4000 base unit. It
must be addressed
to BUC or BDC sub-
units)
N/A
FRW?
Response to
Query
(Target to
Controller)
CUS=x...x
(see description
for details of
arguments)
DAT=mmddyy
(same format as
command
arguments)
EAM=nm
(same format as
command
arguments)
FRE=xxxxx.xxx
(see description
of arguments)
FRW=FWxxxxx

Advertisement

Table of Contents
loading

Table of Contents