MBT-4000 Multi-Band Transceiver System
Remote Control
A.5.6

Optional Message Arguments

Arguments are not required for all messages. Arguments are ASCII codes for the characters 0
to 9 (ASCII codes 48-57), period (ASCII code 46), and comma (ASCII code 44).
A.5.7

End of Packet

Controller-to-Target: This is the 'Carriage Return' character (ASCII code 13).
Target-to-Controller: This is the two-character sequence 'Carriage Return', 'Line Feed' (ASCII
codes 13 and 10).
Both indicate the valid termination of a packet.