Comtech EF Data MBT-4000 Installation And Operation Manual page 61

Multi-band transceiver system
Hide thumbs Also See for MBT-4000:
Table of Contents

Advertisement

MBT-4000 Multi-Band Transceiver System
Remote Control
Command
Valid on
Parameter
(Instruction
Type
Code and
BDC, or
qualifier)
Retrieve
N/A
All
Alarm Status
Arguments
MBT,
for Command
(Note that all arguments are ASCII numeric codes – i.e.,
or Response
BUC
to Query
92 bytes MBT-
Query only.
4000
Used to Query the Alarm status of the unit
64 bytes
(BUC),
Example for MBT-4000 base:
74 bytes
<0001/RAS?{cr}
(BDC),
>0001/RAS={cr}
alphanumeric
15VT1=OK{cr}
7V5T1=OK{cr}
5VLT1=OK{cr}
28VT1=OK{cr}
REFLD=OK{cr}
IICST=OK{cr}
LNAC1=OK{cr}
LNAC2=OK{cr}
LNAW1=OK{cr}
LNAW2=OK{cr}
LNAI1=OK{cr}
LNAI2=OK{cr}{lf}
Example for BDC or BUC:
<0001A1/RAS?{cr}
>0001A1/RAS={cr}
15VLT=OK{cr}
7V5LT=OK{cr}
5VOLT=OK{cr}
REFLD=XX {cr} (reserved for future use)
SYNLD=OK{cr}
HSTMP=OK{cr}
LNACR=OK{cr}{lf}
Note: LNACR will only appear for BDC.
Description of Arguments
ASCII codes between 48 and 57)
A–17
Revision 4
MN/MBT4000.IOM
Response to
Query
Command
(Instruction
(Target to
Code and
Controller)
qualifier)
N/A
RAS?
Response to
Query
(Target to
Controller)
RAS=x....x
(see description
for details of
arguments)

Advertisement

Table of Contents
loading

Table of Contents