Cv-A11 Rs-232C Command List - JAI CV-A11 Operation Manual

Jai progressive scan monochrome ccd camera cv-a11 operation manual
Table of Contents

Advertisement

7.2. CV-A11 RS-232C command list.

Command Name
A – General settings and useful commands
EB
Echo Back
ST
Camera Status request
HP
Online Help request
VN
Firmware version
B – Timing and shutter related commands
SC
Scanning format
TR
Trigger mode
SM
Shutter mode
SH
Shutter speed
PE
Programmable expos.
HC
HD accumulation
C – Signals and polarity
SO
Sync signal
CW
Clock/WEN
TP
Trigger polarity
WP
WEN polarity
D – Gain and analogue signals setting
AS
AGC Switch
AG
AGC Level
GA
Manual gain Level
RP
Rear Potentiometer
SU
Setup Level
WC
White clip Level
GS
Gamma Select
E – Saving and loading data in EEPROM
LD
Load settings from
camera EEPROM
SA
Save settings to
camera EEPROM
*1)
PE=0 has no function in triggered mode. PE=1 is 0.5H in continuous mode
*2)
If positive logic is used (TP=1), the first trigger pulse after power up will be ignored.
!!
Do not try to use commands not shown in the list.
CV-A11
Format
EB=[Param.]<CR><LF>
ST?<CR><LF>
HP?<CR><LF>
VN?<CR><LF>
SC=[Param.]<CR><LF>
TR=[Param.]<CR><LF>
SM=[Param.]<CR><LF>
SH=[Param.]<CR><LF>
PE=[Param.]<CR><LF>
HC=[Param.]<CR><LF>
SO=[Param.]<CR><LF>
CW=[Param.]<CR><LF>
TP=[Param.]<CR><LF>
WP=[Param.]<CR><LF>
AS=[Param.]<CR><LF>
AG=[Param.]<CR><LF>
GA=[Param.]<CR><LF>
RP=[Param.]<CR><LF>
SU=[Param.]<CR><LF>
WC=[Param.]<CR><LF>
GS=[Param.]<CR><LF>
LD=[Param.]<CR><LF>
SA=[Param.]<CR><LF>
- 18 -
Parameter
0=Echo off
1=Echo on
0=full frame
1=1/2 partial
2=1/3 partial
3=1/6 partial
0=normal
1=Edge
2=Pulse width
3=Frame delay
4=Long time
5=Start/stop
6=Smearless
0=Normal
1=Programmab.
0=1/30
1=1/50
2=1/60
3=1/125
4=1/250
5=1/500
6=1/1000
7=1/2000
8=1/4000
9=1/10,000
10=1/20,000
11=1/40,000
12=1/60,000
13=1/80,000
14=1/100,000
1=1.5H
1023=1023.5 H
0=*1),
0=H synchron
1=a-synchron
accumulation
accumulation
0=no sync
1=sync on video
0= WEN out
1=Clock out
0= active low
1= active high
0= active low
1= active high
0=AGC off
1=AGC on
0=low
255=high
0=low
255=high
0=manual gain
1=rear potm.
0=low
255=high
0=low
255=high
0=gamma 1
1=gamma 0.45
0=Factory data
1=User 1 area
2=User 2 area
3=User 3 area
1=User 1 area
2=User 2 area
3=User 3 area
Remarks
Off at power up
Actual setting
Command list
3 letter version
All15 step is valid
in normal trigger
mode.
In all trigger
modes shutter
speeds higher
than 9 will result
in 1/10,000
H= 63.56µsec
a-sync. only for
TR=2 and TR=3
CW=0 if clock not
used
*2)
0= manual gain
Range 0 to 255
Range 0 to 255
Range 0 to 255
Range 0 to 255
Latest used data
area becomes
default at next
power up

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents