Cv-A50/60 Rs-232C Command List - JAI CV-A50 Operation Manual

Industrial monochrome ccd camera
Table of Contents

Advertisement

7.2. CV-A50/60 RS-232C command list.

Command Name
A – General settings and useful commands
EB
Echo Back
ST
Camera Status request
HP
Online Help request
VN
Firmware version
B – Timing and shutter related commands
SC
Scanning format
TR
Trigger mode
SM
Shutter mode
SH
Shutter speed
PE
Programmable expos.
C – Signals and polarity
FR
Accumulation
PC
Pixel clock
TP
Trigger polarity
WP
WEN polarity
D – Gain and analogue signals setting
AS
AGC Switch
AG
AGC Level
GA
Manual gain Level
RP
Rear Potentiometer
SU
Setup Level
WC
White clip Level
GS
Gamma Select
E – Saving and loading data in EEPROM
LD
Load settings from
camera EEPROM
SA
Save settings to
camera EEPROM
*1)
In normal non trigger mode (TR=0) PE<312 for CCIR and PE<262 for EIA. In trigger mode TR=1, EEN will not be correct if
PE>833.
*2)
If positive logic is used (TP=1), the first trigger pulse after power up will be ignored.
!!
Do not try to use commands not shown in the list.
CV-A50 / CV-A60
Format
EB=[Param.]<CR><LF>
ST?<CR><LF>
HP?<CR><LF>
VN?<CR><LF>
SC=[Param.]<CR><LF>
TR=[Param.]<CR><LF>
SM=[Param.]<CR><LF>
SH=[Param.]<CR><LF>
PE=[Param.]<CR><LF>
FR=[Param.]<CR><LF>
PC=[Param.]<CR><LF>
TP=[Param.]<CR><LF>
WP=[Param.]<CR><LF>
AS=[Param.]<CR><LF>
AG=[Param.]<CR><LF>
GA=[Param.]<CR><LF>
RP=[Param.]<CR><LF>
SU=[Param.]<CR><LF>
WC=[Param.]<CR><LF>
GS=[Param.]<CR><LF>
LD=[Param.]<CR><LF>
SA=[Param.]<CR><LF>
- 19 -
Parameter
0=Echo off
1=Echo on
0=Interlaced
1=Non-interl.
2=1/2 partial
3=1/3 partial
0=normal
1=Edge
2=Pulse width
3=Frame delay
4=Long time
5=Start/stop
0=Normal
1=Programmab.
0=Off
1=1/100
0=1/50 (1/60)
1=1/125
2=1/250
3=1/500
4=1/1000
5=1/2000
6=1/4000
7=1/10000
0= No function
1=1.5H
1023=1023.5H
0=Field
1=Frame
0=no clock out
1=clock out
0= active low
1= active high
0= active low
1= active high
0=AGC off
1=AGC on
0=low
255=high
0=low
255=high
0=manual gain
1=rear potm.
0=low
255=high
0=low
255=high
0=gamma 1
1=gamma 0.45
0=Factory data
1=User 1 area
2=User 2 area
3=User 3 area
1=User 1 area
2=User 2 area
3=User 3 area
Remarks
Off at power up
Actual setting
Command list
3 letter version
Partial scanning is
not supported
Continuous only
Trigger modes and
Continuous
CCIR. H=64µsec
EIA, H=63.5µsec
*1)
Should be off
when not used
*2)
0= manual gain
Range 0 to 255
Range 0 to 255
Range 0 to 255
Range 0 to 255
Latest used data
area becomes
default at next
power up

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cv-a60Cv-a50cCv-a60cCv-a50eCv-a60e

Table of Contents