6. Functions and Operations

Apart from the standard continuous operation, the CV-A11 features three external asynchronous
trigger modes (edge pre-select, pulse width controlled and start/stop) and a special frame-delay
readout mode. Long integration time mode is also supported.
In addition, the CV-A11 also provides a partial scan readout function.

6.1. Basic functions

Some of the primary camera functions need a general introduction before the operation modes
are described. The list below shows the primary functions from the command list.
SM
Shutter Mode
SH
Shutter Speed
PE
Programmable Exposure 1.5 H to 1023.5 H
SC
Scanning Format
TR
Trigger Mode
HC
HD Accumulation
The shutter SM can be set to normal (SM=0), where the exposure time is selected from 15 fixed
step with the command SH, or programmable exposure (SM=1). Here the command PE allows
1023 step with 1 line period resolution (63.5 µs) in triggered mode. For normal mode, PE can be
up to 523 for full, 275 for 1/2, 195 for 1/3 and 115 for 1/6 partial scan.
The CCD scanning format SC can be selected between full or partial scanning. With partial
scanning, only the vertical central part of the CCD sensor is read out with a higher frame rate.
The partial scan is done by a fast dump read out of the lines in the vertical ccd register down to
the top of the partial image. The partial part of the image is read out with normal speed. The
lines below the partial image are read out and dumped with a high speed.
The accumulation mode HC is H synchronous (HC=0). For PWC mode (TR =2) and Frame Delay
readout (TR=3) it can also be set to asynchronous accumulation (HC=1).
In H synchronous mode, the exposure in will start at the first HD pulse after the trigger falling
edge. In H asynchronous mode the exposure will start immediately at the leading edge of the
trigger pulse without waiting for the HD. Fig. 9 and fig. 10 shows the details.
HD
Trigger
Accum
X b
Fig. 9. PWC H synchronous accumulation.
In normal continuous mode (TR=0) shutter speed up to 1/100,000 second can be used. In
triggered shutter modes, the shortest shutter time is limited to ≥1,5 H or 1/10,000. In triggered
shutter modes with full and partial scan, the exposure time is not limited to the frame read out
time. It can be longer.
CV-A11
Normal shutter, Programmable Exposure
Off to 1/100,000 second
Full frame, 1/2 partial, 1/3, 1/6 partial
Normal, Edge, PWC, frame delay readout
Long time exposure, start-stop, smearless (Edge)
H Synchronous, H Asynchronous.
Imaged scene
Imaged scene
Fig. 8. Partial scanning.
- 6 -
648 pixels
648 pixels
Partial scanning.
Partial scanning.
Aspect ratio correct
Aspect ratio correct
HD
Trigger
Accum
X b
Fig 10. PWC asynchronous accumulation.