rmon alarm

Use this command to set the alarm and MIB object. Cancel the
alarm with the no form of this command.
Global configuration
rmon alarm <index><variable><interval>{delta | absolute}
rising-threshold <value>[<event-index>] falling-threshold
<value>[<event-index>][owner <string>]
no rmon alarm <index>
<index>
<variable>
<interval>
delta
absolute
rising-threshold
<value>
<event-index>
Confidential and Proprietary Information of ZTE CORPORATION
Index number, range: 1~65535
MIB variable to be monitored, which must be
an MIB variable that can be converted into an
integer, with 1~64 characters
Time interval for monitoring the above
variable in seconds, range: 1~2147483647
Indicates to compare the increment with the
threshold
Indicates to directly compare the value of the
selected variable with the threshold
Rising threshold of the sampling statistics,
range: -2147483647~2147483647
Event index if the threshold is exceeded,
range: 1~65535