KEYPAD MESSAGES

The GEM-RP1CAe2/GEM-K1CA Keypad can display the following messages. The GEM-RP2ASe2 and GEM-K2AS keypads will dis-
play similar abbreviated messages that may scroll through two screens.
SYSTEM READY CW1 - All zones operating; system can be
armed. GEM-RP1CAe2 only: C = Chime Mode on; W =
Watch Mode on; 1-8 = Area.
PLEASE WAIT - Panel reporting to central station on arming.
Wait for ringback signal to exit.
EXIT TIME XXX SI1 - Exit delay in progress. XXX = exit time
remaining in 10-second decrements; GEM-RP1CAe2 only:
S = Service Code active; I = arming with Instant protection;
1-8 = Area.
ENTRY TIME XXX - Entry delay in progress. XXX = entry time
remaining in 10-second decrements.
SYSTEM ARMED SI1 - Panel armed. GEM-RP1CAe2 only: S =
Service Code active; I = arming with Instant protection; 1-8
= Area.
CHECK STATUS CAW - One or more zones not secured. Dis-
play status for zone description(s). GEM-RP1CAe2 only: C
= Chime Mode on; W = Sensor Watch Mode on
CAN'T ARM/ZONES NOT NORMAL - Arming attempted with
Priority Zone in trouble. Secure zone to arm.
DAY ZONE TRBL - Trouble condition on Day Zone, followed by
one or more zone descriptions.
INVALID ENTRY/TRY AGAIN - Wrong code/time/area number
entered.
CAN'T ARM SYSTEM - Arming attempted with System Trouble
present. Press the
C
tem.
ALARM - Alarm condition, followed by one or more zone de-
scriptions.
****FIRE**** - Fire alarm condition, followed by one or more zone
descriptions.
FIRE TROUBLE - Trouble condition on a Fire Zone.
C
button to silence the sounder. Correct the trouble,
then press the
C
button again.
FIRE ALARM - Alarm condition on a Fire Zone.
button to silence the sounder. Correct the cause of
C
the alarm, then press the
ZONES BYPASSED - (When Zones Bypassed displayed) Indi-
cates zones that have been deactivated.
OV(R-) - Overview Mode (Status of up to 8 areas): R=Zone
Ready; also, Z=Zone Fault; A=Armed; B=Burglary Output;
F=Fire Alarm; T=Fire Trouble; C=Check Trouble; Display
Mode.
SYSTEM TROUBLE - A System Trouble display will be followed
by one or more of the following error codes:
E01-00 - AC POWER FAIL. Power failure. Check power
transformer. Check for blown fuse or circuit breaker;
general power outage.
E02-00 - LOW BATTERY. Battery below 11 volts. If not
recharged within 24 hours, replace it.
E03-00 - COMM FAIL.
central station. Note: Will also display if panel improp-
erly programmed to report; i.e., Report Alarm, Report
Codes, Subscriber ID Numbers, etc.
grammed.
E04-NN - WL TRBL. Wireless transmitter supervisory fail-
ure. NN = transmitter number.
E05-NN - WL LOBATT. RF transmitter low battery. NN =
transmitter number.
E06-NN - RF REC TROUBLE. RF receiver response trou-
ble. NN = receiver number.
X
GEM-P9600 Installation Instructions
button and then arm the sys-
Press
Press the
C
button again.
Unsuccessful communication to
must be pro-
E07-00 - DOWNLOAD FAIL. Download failure.
E08-00 - TELCO LINE1 FAIL.
(system trouble displays after a programmed delay).
E09-00 - NOT PROGRAMMED. System cold start.
E10-NN - BURG KEYPAD TRBL. Keypad response failure.
NN = keypad number.
E11-NN - BURG KPD TAMPER. Keypad cover removed.
NN = keypad number.
E12-NN - BURG EZM TRBL. Expansion zone module fail-
ure. NN = module number.
E13-NN - BURG EZM TAMPER.
moved. NN = module number.
E14-NN - RELAY BOARD TRBL. Relay board response
failure. NN = relay board number.
E15-NN - WL TAMPER. Transmitter cover removed. NN =
transmitter number.
E16-NN - RF REC JAMMED. Receiver jammed. NN = re-
ceiver number.
E17-NN - RF REC TAMPER. Receiver cover removed. NN
= receiver number.
E18-NN - LOBATT KEYFOB. Key fob transmitter low bat-
tery. NN = key fob transmitter number.
E19-00 - USER MEM ERROR. Internal memory error. Se-
lect RESET SYSTEM TBL. Press the
the
C
button.
E20-00 - DEALER MEM ERROR. Same as above.
E22-NN - PIR SENSOR TRBL.
Supervision Zone within programmed Sensor-Watch
time.
NN = Zone number.
(
E
) button at "RESET SENSOR MSG" function display.
E23-00 - BURG BUS FAILED.
Check Terminals 11/12.
E24-00 - TIME FOR SERVICE. A service message can be
programmed through the PCD3000 Quickloader
(event-schedule screen) to remind the user to arrange
for scheduled maintenance. At the programmed date
and time, the keypad sounder will start to pulse and
the display will read "TIME FOR SERVICE" (GEM-RP1CAe2)
or "SERV" (GEM-RP2ASe2). This condition will behave
as a system trouble and may be cleared as such, i.e.,
press
C
to silence sounder; access RESET
SYSTEM TRBL, then press the
E27-00 - Printer Failure. Call installing company for service.
E39-00 - RF CAPACITY TRBL. Receiver capacity error.
E51-00 - Alarm Output Supervisory.
E99-00 - Keypad panic shorted too long. GEM-RP2ASe2 /
GEM-RP3DGTL only.
NN OUT OF SYSTEM - Keypad inoperative. NN = keypad
number.
ALARM - (After panel is disarmed) displays zones violated.
FAULT FIND - Fault-find Mode activated.
LOCATE - Locate Mode activated.
L
WI742D 5/03
Telephone line failure
EZM module cover re
J
button, then
No trip detected on PIR
To reset, press YES
Failure of 4-wire bus.