Factory Default Description - Gemini GEM-P9600 User Manual

Control panel/communicator
Hide thumbs Also See for GEM-P9600:
Table of Contents

Advertisement

WI742D 5/03
GEM-P9600 FACTORY DEFAULT DESCRIPTION
The Factory Program of the GEM-P9600 will change with the release of the new version that complies with Security Industry As-
sociation False Alarm Reduction Control Panel-01 Standard (SIA FAR CP-01).
Out of Box Panel Operation (After CP-01 Changes)
The following describes the new panel factory defaults:
With this new SIA CP-01 compliant panels, the Easy Program Menu has been increased to allow several additional features to
be programmed in the Menu, rather than requiring that these features be programmed through the Direct Address programming
method. If you enter Dealer Program Mode, you will be required to first enter Easy Program Mode and answer Easy Program
Mode questions before making any needed changes to the factory program via Direct Address Programming Mode.
Once the panel is removed from its box, you have two choices: (1) Enter Dealer Program Mode in order to allow the EZ Pro-
gram Menu to appear, then answer the questions; (2) Upload the Factory Default Program to PCD-Windows, make desired
changes, and re-download this modified PCD-Windows program back to the panel.
A critical addition to the Easy Program Menu is the question "Enable CP-01 Features? Y/N". If the answer to this question is
"No" then the following changes to the program occur:
1.
All zones (96 in the GEM-P9600, 32 in GEM-P3200) are programmed for Priority, Selective Bypass, Alarm Output, Auto
Reset and Swinger Shutdown. Only the zones selected by the first EPM question "How many Zones" are programmed
for Area 1.
2.
Default User 1 Code = "123" and it is set up to arm Area 1 and be a user program code.
3.
Keypad Time/Date Display enabled.
4.
All zones are programmed with report codes and as burg/fire alarm types depending on whether they were selected as
fire zones. Zones not selected as fire are burg type.
5.
The reporting format is selectable in the Easy Program Mode.
6.
Touch Tone with Rotary Back-up is enabled.
7.
Exit Delay = 60 seconds.
8.
Entry Delay 1 and 2 are both 30 seconds.
9.
AC Fail Report Delay is 60 minutes.
10. Alarm and Pulse Alarm time-outs are 15 minutes.
11. Chime is set to 2 seconds.
12. Change Pulse Alarm to Cadence Alarm is enabled.
13. Auto Reset after Alarm Time-Out is enabled.
If the answer to the question "Enable CP-01 Features? Y/N" is "Yes", then the following changes to the above program occur:
1.
Auto Reset and Swinger Shutdown are removed from burg zones.
2.
2421-Bit 3 "Aux. Output Chirp on Keyfob Arm/Disarm" is enabled.
3.
2421-Bit 0 "Automatic Interior Bypass" is enabled.
4.
2422-Bit 6 "Enable Bell Output on Keyfob Arming" is enabled.
5.
3905-Bit 1 "Exit Time Restart" is enabled.
6.
3905-Bit 2 "Sound Alarm on Exit Error" is enabled.
7.
3905-Bit 3 "Report Exit Error/Recent Closing" is enabled.
8.
3905-Bit 4 "Digital Dialer Report Enter/Exit Test Mode" is enabled.
9.
3905-Bit 5 "Enable CP-01 Limits" is enabled.
10. 2406 "Abort Delay" is changed to 30 seconds.
11. 4082 "Report Cancel Window" is set to 7 minutes .
12. 3905-Bit 7 "Enable Ambush Code Type in User Assignment" enabled.
Subsequent entering of the Dealer Program allows only a subset of the Easy Program Menu which does not include the ques-
tion "Enable CP-01 Features" and prevents the existing program from being deleted, but allows the system to be expanded.
The CP-01 Quick Reference Chart (see
"Enable CP-01" (above) should be reviewed before installing the panel.
Note: When 3905-5 "Enable CP-01 Limits" is enabled, the Exit Delay keypad sounder (including the Exit Urgency sound during
the final 10 seconds of the Exit Delay) is enabled.
L
NAPCO Security Systems
pages 61-62
of this manual) and the explanation of the Easy Program Question
X
GEM-P9600 Installation Instructions
!
Page 63

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents