Glossary - Gemini GEM-P9600 User Manual

Control panel/communicator
Hide thumbs Also See for GEM-P9600:
Table of Contents

Advertisement

WI742D 5/03

GLOSSARY

Displayed messages shown are for the GEM-RP1CAe2 and GEM-K1CA keypads. GEM-RP2ASe2/GEM-K2AS and
Note:
GEM-RP3DGTL/GEM-K3DGTL messages are similar but abbreviated. Refer to the appropriate GEM-P9600 Programming Man-
ual (WI777 and/or WI1185) for address numbers.
Abort Delay (Do not program for UL Applications.)
An Abort Delay is a delay period that allows cancellation of the central-station report by disarming the control panel before a report is
sent. If Enable CP-01 Limits (Address 3905 bit 5) is enabled, the Abort Delay is 30 seconds, which can be removed, or increased. In
addition, if an attempt is made to change the Abort Delay to less than 15 seconds or more than 45 seconds the time will be entered
as 30 seconds. If enable CP-01 Limits is NOT enabled, the factory delay time will be set at 30 seconds, and can be deleted or in-
creased to 255 seconds. Refer to "Enable CP-01 Limits" in this glossary. Enable program zones for Abort Delay
1322, 1422, 1522, 1622, 1722, 1822, 1922, 2022,
may be selected for zones
(Address 1208, 1308, 1408, 1508, 1608, 1708, 1808, 1908, 2008,
alarm with no alarm outputs or central station reporting for the duration of abort delay time.
Note: If Abort Delay is selected for a 24-Hour Zone, the zone must be cleared before disarming the area.
AC Failure
AC-Fail Report Delay
If AC power is removed from the control panel, "E01-00 AC POWER FAIL" will display at the keypad with a flashing "SYS/TRBL" reminder
and a pulsing sounder. Press the
READY" will appear in the display. If a User Code is entered within 5 minutes, the panel may be armed successfully. After 5 minutes,
the system trouble will again display.
AC Failure may be programmed to activate the burglary output or any external relay, and/or report to a central station (program
Panel AC-Fail Report). An alarm and/or restore report to the central station will occur immediately unless an AC-Fail Report Delay is
programmed (see Time Selection). AC Failure is logged immediately upon detection.
Access Control; Access Control (Panel Access) on Aux Output; Aux Output Access Control Time; Panel Access
NOTE: The GEM-P9600 has not been evaluated by UL for compliance with UL294 (Access Control Systems).
The Aux Output can be programmed to activate for a programmable period of time (2 to 254 sec.). This allows it to be used for ac-
cess functions such as opening and closing a garage door, or remotely activating an electric door strike through an RB1000 relay.
This is achieved by programming a new KeyFob option, Access on Aux Output, into the Aux. 1 or Aux. 2 option locations on the Wire-
less KeyFobs screen. This feature also requires a valid time to be entered into the Aux Output Access Control in the Time Selection
Screen.
If Access Control on Aux Output (Address 2418 bit 4) is selected, entering the Access Code (see User Code Programming in Easy
Menu Driven Mode Programming) while disarmed will trip the panel's Aux Output. (This is commonly used to activate a door strike for
the purposes of remotely unlocking a door). Each keypad is individually selected for Panel Access
gram
Aux
Output Access Control Timeout
1124, 1134,
1144, 1154, 1164, 1174, 1184, 1194, 1215, 1315, 1415, 1515, 1615, 1715, 1815, 1915, 2015,
alarm. Do not program Aux Output Chirp on Keyfob Arm/Disarm (Address 2421), unless Enable Bell Output on Keyfob Arming is se-
lected also (Address 2422).
Panel Access is selectable for any keypad 1–7 by selecting the appropriate Area Option of any User Code (see User Code Program-
ming in Easy Menu Driven Mode Programming); select the Panel Access option (Address 2440-2454) for those keypad numbers (1–
15) that are to respond to the User Code. However, if the Access Option is programmed, the code will no longer function as an Arm/
Disarm Code.
Entering a valid code at the keypad will cause the Aux output on panel to turn on for the programmed time. The RB1000 Relay may
be used to activate a door strike, and power to the door strike should be supplied from an independent power source.
Access, Garage Door Opener Control by KeyFob.
The Auxiliary Output can be programmed to activate by KeyFob, providing access functions such as opening and closing a ga-
rage door, or remotely activating an electric door strike. This is achieved by programming Access on Aux. Output, into the Aux. 1 or
Aux. 2 option locations on the Wireless KeyFobs screen. This feature also requires a valid time to be entered into the Auxiliary Relay
Access Control time in the Time Selection Screen.
Access Number for Outside Line
Some subscribers will have a telephone system that requires one digit to access an outside line. The first dial tone encountered
(prior to the access number) may have a frequency that is different from that of the accessed dial tone (440Hz). One or more 4-
second Pre-Dial Delay "D"s may be entered before the access number instead of a dial tone with frequency "E". See Pre-Dial Delay;
Telephone Numbers. (Note: The panel features automatic dial-tone detection and will normally not require any "E"s. To disable this
feature, program an "8" in Address Location 4084.)
If the subscriber's system uses an access number, contact the telephone-equipment supplier to find out if a dial tone other than
440Hz is received prior to dialing the access number. If the communicator must delay before dialing the access number instead of
attempting to recognize the dial tone, find out how many 4-second delays must be programmed.
L
NAPCO Security Systems
2122) and select an Abort Delay Time
C
button to silence the sounder; the "SYS/TRBL" as a reminder will remain on and "SYSTEM
(Address
2402). NOTE: Do not program the
(Address
2406). Also, a Pre-Alarm Warning
2108) allowing a keypad indication of
(Address
Aux
Output (Address 1086, 1098, 1110,
X
GEM-P9600 Installation Instructions
!
Page 31
(Address 1222,
2440-2454). Also pro-
2115) as an output on

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents