Gemini GEM-RP1CAe2 Operating Manual
Gemini GEM-RP1CAe2 Operating Manual

Gemini GEM-RP1CAe2 Operating Manual

Keypad computerized security system
Hide thumbs Also See for GEM-RP1CAe2:

Advertisement

OPERATING GUIDE for your
G E M I N I
C O M P U T E R I Z E D S E C U R I T Y S Y S T E M
© NAPCO 2000
GEM-RP1CAe2 KEYPAD
SYSTEM ARMED
SYSTEM ARMED
1 1 2 2 /01/
/01/00 00 12:00 AM
A 1 2 3
B 4 5 6
C 7 8 9 0
12:00 AM
NEXT/YES
E
J
PRIOR/NO
F
AREA
G
DESIGN PATS. PENDING
1

Advertisement

Table of Contents
loading

Summary of Contents for Gemini GEM-RP1CAe2

  • Page 1 OPERATING GUIDE for your GEM-RP1CAe2 KEYPAD G E M I N I SYSTEM ARMED SYSTEM ARMED 1 1 2 2 /01/ /01/00 00 12:00 AM 12:00 AM NEXT/YES A 1 2 3 PRIOR/NO B 4 5 6 AREA C 7 8 9 0 C O M P U T E R I Z E D S E C U R I T Y S Y S T E M ©...
  • Page 2: Napco

    I N T R O D U C T I O N The GEM-RP1CAe2 is a “smart” user- reference. Check the Glossary for an Regardless of how your system has friendly, menu-driven keypad designed for explanation of terms that may be unfamiliar been configured, rest assured that it has your Napco control panel.
  • Page 3: Table Of Contents

    T A B L E O F C O N T E N T S TO SILENCE AN ALARM, ENTER YOUR T A B L E C O N T E N T S CODE, AND PRESS Section Page KEYPAD CONTROLS & INDICATORS ...........4 FOR SERVICE, CALL: _____________________ SETTING THE ALARM (ARMING) WHEN LEAVING ......6 CENTRAL STATION: ______________________...
  • Page 4: Keypad Controls & Indicators

    K E Y P A D C O N T R O L S & I N D I C A T O R S G E M I N I SYSTEM ARMED SYSTEM ARMED 01/01/00 12:00 AM 01/01/00 12:00 AM NEXT/YES PRIOR/NO AREA...
  • Page 5 K E Y P A D C O N T R O L S & I N D I C A T O R S Window. Displays system status (2)Unbypasses a bypassed violation. (2) Scrolls window messages, zone descriptions, zone. display backward (PRIOR).
  • Page 6: Setting The Alarm (Arming) When Leaving

    S E T T I N G T H E A L A R M ( A R M I N G ) W H E N L E A V I N G Arming the System SYSTEM READY 1. Check the keypad. The green STATUS light must be on in order to arm. If the green light is off, “ZONES FAULTED”...
  • Page 7 S E T T I N G T H E A L A R M ( A R M I N G ) W H E N L E A V I N G System Trouble SYSTEM TROUBLE If you attempt to arm with a “SYSTEM TROUBLE” display alternating with an indicated trouble code (e.g. SYS/TRBL “E02-00”...
  • Page 8: Protecting Yourself While On The Premises

    P R O T E C T I N G Y O U R S E L F W H I L E O N T H E P R E M I S E S Bypassing Interior Zones Interior Zones, when bypassed, allow free movement within the home while the protection of armed perimeter zones is maintained. To bypass Interior Zones, press and enter your User Code followed by Your system may have provisions for two groups of Interior Zones.
  • Page 9 P R O T E C T I N G Y O U R S E L F W H I L E O N T H E P R E M I S E S Easy Exit (Optional - Easy Exit programmed? Your system may have been programmed for Easy Exit, which allows a user to exit the premises while the system is armed.
  • Page 10: Turning Off The Alarm (Disarming) When Returning

    T U R N I N G O F F T H E A L A R M ( D I S A R M I N G ) W H E N R E T U R N I N G Disarming the System E N T R Y T I M E X X X 1 Enter your premises through the Entry/Exit door.
  • Page 11: Fire Protection

    F I R E P R O T E C T I O N (Applicable only where local ordinance permits use of this alarm control panel for fire protection.) Fire-Zone Alarm F I R E A L A R M FIRE If a fire is detected, “FIRE ALARM”...
  • Page 12 F I R E P R O T E C T I O N Preparing a Fire Escape Plan alternate route through the window. Everyone in his room with the doors closed. If the door is cool, brace your Even with the most advanced fire shoulder against it and open it One person sounds the alarm.
  • Page 13 F I R E P R O T E C T I O N Floorplan Floorplan...
  • Page 14 F I R E P R O T E C T I O N LIMITATIONS OF FIRE ALARM WARNING SYSTEM provide early-enough warning for a likely to alert those on a different level. Although a fire alarm system may be of a variety of reasons: (a) they may not Even those who are awake may not hear reliable and state-of- the-art design,...
  • Page 15: Keypad Functions

    K E Y P A D F U N C T I O N S The keypad can provide access to a wide assortment of utility functions. The functions are displayed in a prompting “YES/NO” format. In all UL-listed or high-security installations, a valid User Code must first be To enter the Function Menu, press entered followed by 2 To skip a function, answer NO (...
  • Page 16 K E Y P A D F U N C T I O N S Activate Bell Test? Activates the alarm (while disarmed) for about 2 seconds and A C T I V A T E B E L L T E S T Y / N performs a battery test.
  • Page 17 K E Y P A D F U N C T I O N S Reset System Trouble? System troubles display and sound at the keypad. R E S E T Correcting the trouble will clear most indications, however the following error codes S Y S T R B L Y / N will require manual reset: E13;...
  • Page 18 K E Y P A D F U N C T I O N S Activate Telephone Test? Sends a (Telephone Test programmed? NO). A C T I V A T E communicator test to the central station. A communication failure will be D I A L E R T E S T Y / N indicated at the keypad by a system trouble “E03-FAIL TO COMM”...
  • Page 19 K E Y P A D F U N C T I O N S A C T I V A T E Activate Program? Activates the Program Mode from Keypad No. 1. Note: This P R O G R A M Y / N feature is disabled while armed.
  • Page 20: Central-Station Monitoring

    C E N T R A L S T A T I O N M O N I T O R I N G Opening and/or Closing Your alarm specialist may have arming (Closing Report), the central Reporting. Your system can notify programmed your system to be station will acknowledge arming.
  • Page 21: Advanced Features

    A D V A N C E D F E A T U R E S Security Bypass/Unbypass (Security Bypass programmed? NO). In high-security applications, zones may be bypassed (or unbypassed) only if a valid code is entered first, as follows: 1 Enter a User Code valid for bypass, then press Press then the zone number (or vice versa) to deactivate that zone.
  • Page 22: Programming User Codes

    P R O G R A M M I N G ( O P T I O N A L ) User Program Mode Your Installer has programmed into your system a special User Program Code which can be used to not only Arm and Disarm the system, but also to enter the User Program Mode, where you can program other User Codes, Zone Descriptions and also set the system Time and Date.
  • Page 23 P R O G R A M M I N G ( O P T I O N A L ) Reviewing a Programmed User Code To review an existing User Code, enter the 2-digit user number and the corresponding User Code will display. Exiting the User Program Mode When you have completed programming or erasing User Codes, press to exit the User Program Mode.
  • Page 24 P R O G R A M M I N G ( O P T I O N A L ) Programming Zone Descriptions The zone descriptions which appear on the keypad display may be programmed in the User Program Mode. Enter the User Program Mode A C T I V A T E 1 Enter...
  • Page 25 P R O G R A M M I N G ( O P T I O N A L ) Programming the system Date and Time. The User Program Mode may also be used to set the system Date and Time which display on the Enter the User Program Mode A C T I V A T E 1 Enter your User Code, then press...
  • Page 26: Keypad Messages

    K E Y P A D M E S S A G E S The keypad can display the following functional messages. Other diagnostic messages are available for the installer or servicer. Should any unfamiliar message appear, call your dealer for service. S Y S T E M R E A D Y All zones operating;...
  • Page 27 K E Y P A D M E S S A G E S * * * * A L A R M * * * * Alarm condition, followed by zone description(s). “ALARM” and zones will display after system is disarmed. Note zones, then press to clear keypad.
  • Page 28 K E Y P A D M E S S A G E S A T T E M P T I N G T O The system is in the process of reporting a cancel signal to central station which will C A N C E L cancel the alarm which it has just reported.
  • Page 29: Glossary

    G L O S S A R Y Following are brief descriptions of terms and features used herein that may be unfamiliar to you. Some of the features are programmable options that may or may not apply to your particular system. Abort Delay: Arming/Disarming - Closing Window:...
  • Page 30 G L O S S A R Y Exit/Entry Delays: Separate pressing together with battery. F Check In: delays that let you exit and (Wireless systems will alert enter your premises without only) Periodic test report from the central station of a fire, setting off an alarm when the transmitter (if a report is not auxiliary, or police emergency.
  • Page 31 G L O S S A R Y 24-Hour Zone: A zone that is armed System Trouble: devices. Entry delay only occurs if A problem (low re-entry takes place through the and ready at all times to respond battery, power failure, etc.) normal exit/entry door first.
  • Page 32: System Trouble Error Codes

    S Y S T E M T R O U B L E E R R O R C O D E S Your control panel is capable of detecting a variety of troubles that may affect system performance. In the unlikely event that a problem should occur, the SYS TBL (system trouble) icon will display on the left side of keypad window along with one or more of the following error codes.
  • Page 33 S Y S T E M T R O U B L E E R R O R C O D E S Trouble System Trouble Action Indication Condition E04-NN Wireless Transmitter A problem has been detected with a wireless transmitter. Call installing company for service Supervisory Failure E05-NN Wireless Transmitter...
  • Page 34 S Y S T E M T R O U B L E E R R O R C O D E S Trouble System Trouble Action Indication Condition E10-NN Keypad Response Call installing company for service. E11-NN Keypad Tamper A keypad has been removed from the wall.
  • Page 35 S Y S T E M T R O U B L E E R R O R C O D E S Trouble System Trouble Action Indication Condition E19-00 User Program Call installing company for service. Memory E20-00 Dealer Program Call installing company for service.
  • Page 36 S Y S T E M T R O U B L E E R R O R C O D E S Trouble System Trouble Action Indication Condition E41-NN Fire Trouble A problem has been detected on the Fire zone indicated. Call installing company for service. E51-00 Bell/Siren Trouble There is a problem with the Bell or Siren.
  • Page 37: Troubleshooting

    T R O U B L E S H O O T I N G What do I do if... For more info... I try to arm my system but the keypad just displays “ZONES NOT NORMAL” and “CAN’T ARM SYSTEM”...
  • Page 38 N O T E S...
  • Page 39 N O T E S...
  • Page 40: Napco Limited Warranty

    NAPCO LIMITED WARRANTY NAPCO SECURITY SYSTEMS, INC. (NAPCO) warrants its products to be free from manufacturing representations, whether oral or written, are either merged herein or are expressly canceled. NAPCO defects in materials and workmanship for thirty-six months following the date of manufacture. NAPCO neither assumes, nor authorizes any other person purporting to act on its behalf to modify, to change, will, within said period, at its option, repair or replace any product failing to operate correctly without or to assume for it, any other warranty or liability concerning its products.

Table of Contents