Relay Control - Gemini GEM-P9600 User Manual

Control panel/communicator
Hide thumbs Also See for GEM-P9600:
Table of Contents

Advertisement

WI742D 5/03
DISPLAY AUTO ARM SCHD
Press the YES button to display the autoarm schedule programmed by the PCD-Windows software. Use NEXT and
PRIOR button to scroll forward and back through the week. While the programmed schedule cannot be changed at the key-
pad, autoarming may be delayed up to four hours at the keypad, or it may be totally disabled, up to one week in advance. Se-
lect the day using the NEXT and PRIOR buttons. Then select the delay (1-4 hours) or disable using the the
minutes prior to autoarming, the siren will sound a 2-second warning and the keypad will begin a 15-minute countdown with the
sounder pulsing. Within this countdown window, arming may be delayed an additional 1 to 4 hours (using TO ARM IN 1-4HRS
function), or autoarming may be canceled by arming and disarming the panel.
ACTIVATE PROGRAM
At Keypad No. 1, press the YES button to activate the User Program (Program-1) Mode or Dealer Program (Program-2)
Mode, depending upon the code entered. Scroll through the programmable functions using NEXT the button and PRIOR the
button. To exit this mode at any time, press
ACTIVATE DOWNLOAD
Used on-site for remote downloading of a control-panel program from the PCD-Windows. Press the YES button to initiate
the data transfer.
DISPLAY RF XMITTER STAT
!
Press the YES button to check the status of up to 96 transmitters. The keypad will display:
!
zone number (Z01-Z96)
!
transmitter ID code number (6 digits)
!
point number (PT1-PT4; "9" for unsupervised)
!
status of transmitter:
NODATA: transmission not yet received
NORMAL: transmitter's zone normal;
FAULT: transmitter's zone open;
LOBATT: transmitter battery low;
TAMPER: transmitter case open;
S.FAIL: supervisory failure (test transmission not received within programmed time);
!
relative signal strength of the last transmission, on a scale of 1-10 (10 being the strongest). ("SS—" indicates trans-
mission not yet received). Note: A signal strength of 3 or less is an indication that reception may be unreliable. In such
cases, the use of an additional receiver located closer to the transmitter is recommended. If two receivers are connected to
the GEM-P9600, only the higher signal strength of the two will be displayed.

RELAY CONTROL

Press the YES button to check the status (all on or all off) of up to 8 groups programmed with any combination of up to 96
available external relays. The group number will display with a related description. Scroll through the groups using the NEXT
and PRIOR buttons; change the status of the displayed group by pressing the
L
NAPCO Security Systems
(Not for UL Installations)
. Note: Keypad No. 1 may be located in any area.
CC
U
button.
X
GEM-P9600 Installation Instructions
!
Page 29
U
button. Fifteen

Hide quick links:

Advertisement

Table of Contents
loading