Gemini GEM-P9600 User Manual page 38

Control panel/communicator
Hide thumbs Also See for GEM-P9600:
Table of Contents

Advertisement

!
Page 38
star button (entered as a "B" from the keypad) and the 2 subsequent digits from the Central Station telephone number.
Disable Callback Download See Callback-Method Download
Disable Code Required for Easy Bypass See Selective Bypass (Do not program in UL Installations)
Disable Code Required for Function Mode Level 1
Intended primarily for residential applications, this feature eliminates the user code requirement to access the Function Mode (for
Level-1 Users only), rendering the system more user friendly.
Disable Fire Reset (by Area)
Normally, pressing the
C
for any area, the
C
button will no longer activate the Reset Output so that the integrity of the smoke detector's Alarm Memory
feature (LED indication) will be maintained. Also see Alarm Outputs; Smoke Detectors.
Disable Function-Mode Download See Callback-Method Download
Disable Openings/Closings
Provides the flexibility of disabling openings and/or closings from any area(s).
Disable Wait-for-Handshake/Kissoff
Causes data transmission to start immediately after the telephone number.
Disable Wait-for-Silence (Pager Format)
Causes data transmission to start immediately after the pager telephone number.
Double Reporting See Report Telco 3
Download Security Code See Master Security Code
Download To an Armed Panel
This allows the panel to accept a download even if Armed. However if the programming to be altered effects the arming profile of
the control, such as zone features, it is recommended that the panel be disarmed and then rearmed to allow these changes to be
processed properly. Any program changes such as adding/changing user codes, adding users to an area, or changing Entry/Exit
Delays will be processed properly with the panel armed.
Don't Clear Aux. Relay with Arm/Disarm
Used in conjunction with Key-Fob Option "C" above to prevent a disarm from resetting the Aux. Relay.
"E" Lugs (E3, E5, E7, E9, E10, E11, E14, E18, E19, E22)
E9 - See Fire Lug
E10 - See Burglary Lug
E19 - See Veri-Phone: Silence All Outputs During Audio Session
E22 - Common terminal for Reset Relay. Use Napco Part No. WL1 for field wiring.
Easy Arming
Permits quick arming by simply pressing the
grammed for Easy Arming (see Keypad Features). Disarming still requires entry of a valid user code. Do not program Easy Arming
in UL installations. If closings are reported, Easy Arming will report as User 99.
Easy Exit (Not Evaluated by UL)
While armed in the Interior Bypass/Stay Mode, Easy Exit can be initiated by pressing
allowing a User to exit an armed premises without disarming and rearming the system.
Easy Setup for RF Only
Removes all EZMs automatically programmed in the menu-driven Keypad Program Mode. This must be the last step in the pro-
gramming menu. Access Location 4090, then press the
Enable Bell Output on Keyfob Arming
This feature is associated with AUX. OUTPUT CHIRP ON KEYFOB ARM/DISARM
keyfob arm/disarm is transmitted to the PGM2 output. Selecting "ENABLE BELL OUTPUT CHIRP ON KEYFOB ARMING" causes
the "Bell" to chirp instead of the PGM2 upon remote arming.
Enable Burg Output Warning On Entry
Causes the Burglary Output to "chirp" if the entry door is opened within 60 seconds after exit time has elapsed. This feature may
be useful in cases where a keypad is not within audible range to remind a user to disarm if inadvertently exiting after exit delay has
expired.
Enable CP-01 Limits
(SIA CP-01 Requirement: 4.2.5.1)
When address
3905 bit 5
is enabled, three time limits are enabled as per the SIA CP-01 standards: (1) Exit Delay Time: If an at-
tempt is made to change the Exit Delay time to less than 45 seconds the time will be entered as 60 seconds. The maximum pro-
X
GEM-P9600 Installation Instructions
button will momentarily remove power to the smoke detectors. If Disable Fire Reset is selected
or
P
Q
J
U
or
(Address 2422, Bit 6)
button for 2 seconds. Each keypad may be individually pro-
J
or
button.
(Address 2421-Bit
L
WI742D 5/03
U
. Easy Exit restarts the Exit delay,
3). Normally the chirp on a
NAPCO Security Systems