Wall Or Counter Mounted Salamanders; Model Gfir36C - Garland GF Sentry Series Installation And Operation Manual

Infra-red salamander broilers
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION Continued
4 INSERTED
SCREWS
WITH STANDARD OVEN
4 INSERTED
SCREWS
WITH CONVECTION OVEN
3. Slide the salamander down into the support brackets
installed in step 2, see fi gure 3.
4. Once the salamander is in place, fasten it to the unit on
both sides of the range with the provided #14B x 5/8 hex
washer head tapping screws (detail I) and the center to the
support bracket using 4 of the provided screws (detail II).
PROVIDED
#14B x 5/8 HEX
WASHER HEAD
TAPPING SCREWS
4 PROVIDED
SCREWS
Part # 4526026 Rev. 03 (06/12/14)
DETAIL II
FOR 60" RANGES
DETAIL II
FOR 60" RANGES
DETAIL I
ALL 60" RANGES
DETAIL II
ALL 60" RANGES

Wall Or Counter Mounted Salamanders

Model GFIR36C

1. The appliance shall be located with respect to building
construction and other equipment so as to permit access
to the appliance. Such access and clearance may be
necessary for service and cleaning.
2. Counter models are furnished with 4" (102mm) legs.
Level the unit with a carpenter's level and make minor
adjustments with the threaded leg feet. Ensure that the
counter top can support the weight of the appliance
prior to installation and is comprised of non-combustible
material.
3. Provisions for gas connections, top or rear, should be
taken into consideration at time of installation.
4. If the unit is to be mounted on a non-combustible wall
contact the local authorities for local codes.
5. Position, level, and mark location of the assembled wall
mount kit.
6. Drill wall (locating studs if necessary) to accept suitable
fastening devices.
7. Drill the angle iron bars of the wall mounting kit to match
those drilled in the wall.
8. Install wall mounting kit to wall.
9. Install and secure broiler with bolts supplied.
Page 15

Advertisement

Table of Contents
loading

Table of Contents