Advertisement

INSTALLATION AND
OPERATION MANUAL
GARLAND MODELS:
G80-18B, G80-24B, G80-30B,
G80-36B, G80-48B
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE
OR OTHER FLAMMABLE VAPORS OR
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE PROPERTY DAMAGE, INJURY,
OR DEATH. READ THE INSTALLATION,
OPERATING AND MAINTENANCE
INSTRUCTIONS THOROUGHLY
BEFORE INSTALLING OR
SERVICING THIS EQUIPMENT
Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent
using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been
improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation
instructions provided with the product, or any product that has its serial number defaced, obliterated or removed,
or which has been modified or repaired using unauthorized parts or by unauthorized service agents.
For a list of authorized service agents, please refer to the Garland web site at http://www.garland-group.com.
The information contained herein, (including design and parts specifications), may be superseded and is subject
to change without notice.
GARLAND COMMERCIAL INDUSTRIES
185 East South Street
Freeland, Pennsylvania 18224
Phone: (570) 636-1000
Fax: (570) 636-3903
Part # 1009007 (12/07)
Part # 1009007 (12/07)
APPLIANCE
WARNING:
GARLAND COMMERCIAL RANGES, LTD.
1177 Kamato Road, Mississauga, Ontario L4W 1X4
CANADA
Phone: 905-624-0260
Fax: 905-624-5669
PLEASE READ ALL SECTIONS OF THIS MANUAL
AND RETAIN FOR FUTURE REFERENCE.
THIS PRODUCT HAS BEEN CERTIFIED AS
COMMERCIAL COOKING EQUIPMENT AND
MUST BE INSTALLED BY PROFESSIONAL
PERSONNEL AS SPECIFIED.
IN THE COMMONWEALTH OF MASSACHUSETTS
THIS PRODUCT MUST BE INSTALLED BY A
LICENSED PLUMBER OR GAS FITTER. APPROVAL
NUMBER: G-1-07-05-28
For Your Safety:
Post in a prominent location, instructions to be
followed in the event the user smells gas. This
information shall be obtained by consulting
your local gas supplier.
Enodis UK LTD.
Swallowfi eld Way, Hayes, Middlesex UB3 1DQ ENGLAND
Telephone: 081-561-0433
Fax: 081-848-0041
© 2005 Garland Commercial Industries, Inc.
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the G80-18B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Garland G80-18B

  • Page 1 Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation instructions provided with the product, or any product that has its serial number defaced, obliterated or removed, or which has been modified or repaired using unauthorized parts or by unauthorized service agents.
  • Page 2: Important Information

    IMPORTANT INFORMATION WARNING: This product contains chemicals known to the state of california to cause cancer and/or birth defects or other reproductive harm. Installation and servicing of this product could expose you to airborne particles of glass wool/ceramic fibers. Inhalation of airborne particles of glass wool/ceramic fibers is known to the state of california to cause cancer.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS IMPORTANT INFORMATION......... . 2 DIMENSIONS AND SPECIFICATIONS .
  • Page 4: Dimensions And Specifications

    Width: Depth: Height: No. of Total Input Ship Weight MODEL In (mm) In (mm) In (mm) Burners (BTU/Hr) lbs./kg G80-18B 18 (457) 31-1/4 (794) 22 (559) 45,000 190/86 G80-24B 24 (610) 31-1/4 (794) 22 (559) 60,000 220/98 G80-30B 30 (762)
  • Page 5: Pre Installation

    Garland / U.S. Range will not If concealed damage claim is filed with carrier beyond 15 provide service, warranty, maintenance, or support of any days, GARLAND cannot be held responsible and carrier will kind other than in commercial applications.
  • Page 6: Gas Connections

    INSTALLATION Continued D. The appliance and its individual shut off (supplied by Gas Connections: others) must be disconnected from the gas supply piping G80 – 3/4” NPT Manifold system during any pressure testing of that system at pressures in excess of 1/2 PSIG (3.45 KP2). NOTE: Adequate clearance must be provided for servicing and proper operation.
  • Page 7: Assembly Of Counter Stands

    INSTALLATION Continued Optional Cross Members and Cross Member Mounting Brackets, Reqd. only when Units exceed a 4 ft. Dim. if Reqd. Secure Mounting Holes the pieces together with For Broiler 10 ea. 10-24 Machine Screws to Stand 10 ea. 1/4" Lock Washers 10 ea.
  • Page 8: Installation Of Briquettes And Steel Rods

    MODEL Local and/or National Codes dictate the need of ventilation VERTICAL HORIZONTAL system to be used with this type of equipment. The following G80-18B information is provided to give examples of available ventilation system concepts. G80-24B G80-30B Two basic types of power ventilations are in use today. One...
  • Page 9: Shut Down Instructions

    OPERATION Continued 3. With a lighted taper, light pilot. Air Adjustment 4. Replace briquettes and grid rack sections remove in step 2 1. If necessary, the air is adjusted by rotating the air shutter on burner. The burner must have enough air that the tips Shut Down Instructions of the flames are not yellow, but not so much air that the flames will lift off the burner ports.
  • Page 10: Cleaning And Maintenance

    CLEANING AND MAINTENANCE Cleaning Care of the Grid Racks Exterior Finish Cleaning 1. Grid racks should be wiped daily while still warm, using a Establish a regular schedule. Any spills should be wiped off heavy cloth or other grease absorbing material to remove immediately.
  • Page 11 Part # 1009007 (12/07) Page 11...

This manual is also suitable for:

G80-24bG80-30bG80-36bG80-48b

Table of Contents