Using A Software Frame Burst Start Trigger; Introduction - Basler Camera User Manual

Usb 3.0 cameras
Table of Contents

Advertisement

AW00123402000
6.3.4

Using a Software Frame Burst Start Trigger

6.3.4.1

Introduction

If the camera's Frame Burst Start Trigger Mode parameter is set to on and the Frame Burst Start
Trigger Source parameter is set to software, you must apply a software frame burst start trigger
signal to the camera before you can begin frame acquisition.
A software frame burst start trigger signal is applied by:
Setting the Trigger Selector parameter to Acquisition Start.
Executing a Trigger Software command.
The camera will initially be in a "waiting for frame burst start trigger" acquisition status. It cannot
react to frame trigger signals when in this acquisition status. When a software frame burst start
trigger signal is received by the camera, it will exit the "waiting for frame burst start trigger"
acquisition status and will enter the "waiting for frame start trigger" acquisition status. It can then
react to frame start trigger signals. When the number of frame start trigger signals received by the
camera is equal to the current Acquisition Burst Frame Count parameter setting, the camera will
return to the "waiting for frame burst start trigger" acquisition status. When a new software frame
burst start trigger signal is applied to the camera, it will again exit from the "waiting for frame burst
start trigger" acquisition status and enter the "waiting for frame start trigger" acquisition status.
(Note that as long as the Trigger Selector parameter is set to Frame Burst Start, a software frame
burst start trigger will be applied to the camera each time a Trigger Software command is executed.)
Basler ace USB 3.0
Image Acquisition Control
95

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aca2000-165Aca2040-90Aca3800-14Aca4600-10

Table of Contents