Basler Camera User Manual page 127

Usb 3.0 cameras
Table of Contents

Advertisement

AW00123402000
Frame Start
Triggered
Line 1
Line 2
Line 3
Line 4
Line 5
Line 6
Line 7
Line 8
Line 9
Line 10
Line 11
Line N-2
Line N-1
Line N
Fig. 51: Rolling Shutter in the Global Reset Release Mode
You can calculate the total readout time using this formula:
Total Readout Time = [ tRow x (ROI Height) ] + C
You can calculate the total runtime using the following formula:
Total Runtime = Exposure Time Parameter Setting + Total Readout Time
The cameras can provide an exposure active output signal that will go high when the exposure time
for line one begins and will go low when the exposure time for line one ends.
When the camera is operating with the rolling shutter in the global release mode, the use of flash
lighting is most strongly recommended. The camera supplies a flash window output signal to
facilitate the use of flash lighting.
For more information about the exposure active output signal, see Section 6.8.1 on
For more information about the Exposure Time parameter, see Section 6.5 on
For more information about the flash window, see Section 6.6.2.1 on
Basler ace USB 3.0
Total Runtime
µs
1
Image Acquisition Control
Total Readout Time
Sensor Readout Time
tRow
C
1
= line exposure time
= line readout time