Basler Camera User Manual page 63

Usb 3.0 cameras
Table of Contents

Advertisement

AW00123402000
Figure 32
shows a schematic for the opto-isolated output line.
.
Camera
Fig. 32: Opto-isolated Output Line Schematic with a Typical Voltage Output Circuit (Simplified)
Figure 33 shows a typical circuit you can use to monitor the output line with an LED or an
optocoupler. In this example, the voltage for the external circuit is +24 VDC. Current in the circuit
is limited by an external resistor.
Camera
Fig. 33: Opto-isolated Output Line Schematic with a Typical LED Output Signal at +24 VDC for the External Circuit
(Simplified)
For more information about output line pin assignments and pin numbering, see Section 5.2 on
page
46.
For more information about the Exposure Active signal, see
Basler ace USB 3.0
1
6
3
4
Q1
2
5
1
6
3
4
Q1
2
5
Figure 6.8.1 on page
Physical Interface
Your
Gnd
+3.3 to +24
VDC
Voltage
Output
Signal
to You
Your
Gnd
Your Gnd
+24
VDC
LED
Output
to You