Basler Camera User Manual page 90

Usb 3.0 cameras
Table of Contents

Advertisement

Physical Interface
No electrical signal applied and line inverters enabled:
I/O Line
Electrical Signal /
Electrical Signal
Line 1 (input)
Line 2 (output)
Line 3 (input/output)
Line 4 (input/output)
Table 17: I/O Lines and Line Status With no Electrical Signals Applied and All Line Inverters Enabled
Electrical signals applied and line inverters disabled:
I/O Line
Electrical Signal /
Electrical Signal
Line 1 (input)
Line 2 (output)
Line 3 (input/output)
Line 4 (input/output)
Table 18: I/O Lines and Line Status With Electrical Signals Being Applied and All Line Inverters Disabled
Electrical signals applied and line inverters enabled:
I/O Line
Electrical Signal /
Electrical Signal
Line 1 (input)
Line 2 (output)
Line 3 (input/output)
Line 4 (input/output)
Table 19: I/O Lines and Line Status When Electrical Signals Are Applied With All Line Inverters Enabled
80
LineStatus
Parameter Value
Level
Off/Low
True
Off/Low
False
Off/Low
False
Off/Low
False
LineStatus
Parameter Value
Level
On/High
True
On/High
False
On/High
False
On/High
False
LineStatus
Parameter Value
Level
On/High
False
On/High
True
On/High
True
On/High
True
Binary Expression
of the Line Status
Parameter Value
1
0
0
0
Binary Expression
of the Line Status
Parameter Value
1
0
0
0
Binary Expression
of the Line Status
Parameter Value
0
1
1
1
Basler ace USB 3.0
AW00123402000

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aca2000-165Aca2040-90Aca3800-14Aca4600-10

Table of Contents