Basler Camera User Manual page 61

Usb 3.0 cameras
Table of Contents

Advertisement

AW00123402000
Figure 31
shows a schematic for the opto-isolated input line. The absolute maximum input supply
voltage is +30.0 VDC. The current draw for the input line is between 5 mA and 15 mA.
As an example, the use of a TTL or CMOS logic gate in the external circuit is shown.
Camera
Fig. 31: Opto-isolated Input Line Schematic with a Typical External Circuit (Simplified)
For more information about input line pin assignments and pin numbering, see Section 5.2 on
page
46.
For more information about how to use an externally generated frame start trigger (ExFSTrig) signal
to control acquisition start, see Section 6.4 on
For more information about configuring the input line, see Section 5.11 on
Basler ace USB 3.0
10 Ω
1
6
3
4
2
5
page
99.
Physical Interface
6-pin
Receptacle
Logic Gate
Your
Gnd
page
65.
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aca2000-165Aca2040-90Aca3800-14Aca4600-10

Table of Contents